Submittal
2/2
SERIES
8214
(200)
4
COMBUSTION
339
Specifications - Visual Indication (Suffix VI) (English units)
Specifications - Visual Indication (Suffix VI) (Metric units)
Pipe
Size
(in)
Orifice
Size
(in)
Cv
Flow
Factor
Flow
Capacity ¨
Fuel Gas
Capacity ¨
Operating Pressure
Differential (psi)
Max. Fluid
Temp.°F
Catalog
Number
Const.
Ref. Agency
Watt Ratting/
Class of Coil
Insulation
Approx.
Shipping
Weight (lbs)
ft
3
/hr Btu/hr Min. Max. AC DC
AC DC
UL FM CSA AC DC
GENERAL PURPOSE
3/4 1 5/8 11 593 593,200 0 5 125 77 8214 235VI 6 -
m m m
20/F - 5.3
1 1 5/8 21 1132 1,132,300 0 5 125 77 8214 250VI 6 -
m m m
20/F - 5.2
1 1/4 1 5/8 32 1726 1,725,500 0 5 125 77 8214 260VI 6 -
m m m
20/F - 5.1
1 1/2 1 5/8 35 1887 1,887,200 0 5 125 77 8214 270VI 6 -
m m m
20/F - 4.9
1 1/4
(High Flow)
2 3/32 36 1925 1,925,000 0 5 125 77 8214 265VI 7 -
m m m
20/F - 7.1
1 1/2
(High Flow)
2 3/32 45 2406 2,406,000 0 5 125 77 8214 275VI 7 -
m m m
20/F - 6.8
2 2 3/32 55 2941 2,940,500 0 5 125 77 8214 280VI 7 -
m m m
20/F - 6.4
2
(High Flow)
3 75 4044 4,044,100 0 5 125 - 8214 285VI 8 -
m m m
20/H - 13.3
2 1/2 3 104 5608 5,607,800 0 5 125 - 8214 290VI 8 -
m m m
20/H - 12.8
3 3 105 5662 5,661,700 0 5 125 - 8214 240VI 8 -
m m m
20/H - 11.9
WATERTIGHT
3/4 1 5/8 11 593 593,200 0 5 125 - 8214G236VI 9 9A
m m m
20.1/F 15.8/F 5.3
1 1 5/8 21 1132 1,132,300 0 5 125 - 8214G251VI 9 9A
m m m
20.1/F 15.8/F 5.2
1 1/4 1 5/8 32 1726 1,725,500 0 5 125 - 8214G261VI 9 9A
m m m
20.1/F 15.8/F 5.1
1 1/2 1 5/8 35 1887 1,887,200 0 5 125 - 8214G271VI 9 9A
m m m
20.1/F 15.8/F 4.9
1 1/4
(High
2 3/32 36 1925 1,925,000 0 5 125 - 8214G266VI 10 10A
m m m
20.1/F 15.8/F 7.1
1 1/2
(High
2 3/32 45 2406 2,406,000 0 5 125 - 8214G276VI 10 10A
m m m
20.1/F 15.8/F 6.8
2 2 3/32 55 2941 2,940,500 0 5 125 - 8214G281VI 10 10A
m m m
20.1/F 15.8/F 6.4
m = Safety Shutoff Valve.
¨
1” W.C. Drop @ 2” W.C. Inlet Pressure, 1,000 Btu/cu.ft. or more, 0.64 Specific Gravity Gas.
Pipe
Size
(in)
Orifice
Size
(mm)
Kv
Flow
Factor
Flow
Capacity ¨
Fuel Gas
Capacity ¨
Operating Pressure
Differential (bar)
Max. Fluid
Temp.°C
Catalog
Number
Const.
Ref.
Agency
Watt Ratting/
Class of Coil
Insulation
Approx.
Shipping
Weight (kgs)
(m
3
/hr) Btu/hr Min. Max. AC DC
AC DC
UL FM CSA AC DC
GENERAL PURPOSE
3/4 41 9.4 17 593,200 0 0.3 52 25 8214 235VI 6 -
m m m
20/F - 2.4
1 41 17.9 32 1,132,300 0 0.3 52 25 8214 250VI 6 -
m m m
20/F - 2.4
1 1/4 41 27.3 49 1,725,500 0 0.3 52 25 8214 260VI 6 -
m m m
20/F - 2.3
1 1/2 41 29.9 53 1,887,200 0 0.3 52 25 8214 270VI 6 -
m m m
20/F - 2.2
1 1/4
(High Flow)
53 30.7 55 1,925,000 0 0.3 52 25 8214 265VI 7 -
m m m
20/F - 3.2
1 1/2
(High Flow)
53 38.4 68 2,406,000 0 0.3 52 25 8214 275VI 7 -
m m m
20/F - 3.0
2 53 46.9 83 2,940,500 0 0.3 52 25 8214 280VI 7 -
m m m
20/F - 2.9
2
(High Flow)
76 64.0 115 4,044,100 0 0.3 52 - 8214 285VI 8 -
m m m
20/H - 6.1
2 1/2 76 88.7 159 5,607,800 0 0.3 52 - 8214 290VI 8 -
m m m
20/H - 5.8
3 76 89.6 160 5,661,700 0 0.3 52 - 8214 240VI 8 -
m m m
20/H - 5.4
WATERTIGHT
3/4 41 9.4 17 593,200 0 0.3 52 - 8214G236VI 9 9A
m m m
20.1/F 15.8/F 2.4
1 41 17.9 32 1,132,300 0 0.3 52 - 8214G251VI 9 9A
m m m
20.1/F 15.8/F 2.4
1 1/4 41 27.3 49 1,725,500 0 0.3 52 - 8214G261VI 9 9A
m m m
20.1/F 15.8/F 2.3
1 1/2 41 29.9 53 1,887,200 0 0.3 52 - 8214G271VI 9 9A
m m m
20.1/F 15.8/F 2.2
1 1/4
(High Flow)
53 30.7 55 1,925,000 0 0.3 52 - 8214G266VI 10 10A
m m m
20.1/F 15.8/F 3.2
1 1/2
(High Flow)
53 38.4 68 2,406,000 0 0.3 52 - 8214G276VI 10 10A
m m m
20.1/F 15.8/F 3.0
2 53 46.9 83 2,940,500 0 0.3 52 - 8214G281VI 10 10A
m m m
20.1/F 15.8/F 2.9
m = Safety Shutoff Valve.
¨
1” W.C. Drop @ 2” W.C. Inlet Pressure, 1,000 Btu/cu.ft. or more, 0.64 Specific Gravity