Submittal Sheet

4/2
SERIES
8342
4-WAY
4
% ^ )
Features
Direct acting operation and high flow construction
Direct acting, high flow slide-style valve
Optional flow control regulates cylinder speed
independently, in either direction
Mechanical detent on dual solenoids holds last position,
even after loss of electric power, pneumatics or pressure
No Minimum Operating Pressure Differential required
to shift valve
Dual solenoid operation: solenoid may be energized
momentarily (1/10 second) or continuously
Mountable in any position
Direct Acting
General Service Solenoid Valves
Brass or Stainless Steel Bodies
1/4" and 3/8" NPT
B
E
A
P
Solenoid Enclosures
Nominal Ambient Temp. Ranges
Standard Class F insulation: 32˚F to 125˚F (0˚C to 52˚C)
Optional Class H insulation: 32˚F to 140˚F (0˚C to 60˚C)
Refer to Engineering Section for details.
Approvals
CSA certified. UL listed as General Purpose Valves.
Meets applicable CE directives.
Refer to Engineering Section for details.
Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X.
Optional: Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9.
(To order, add prefix “EF” to catalog number.)
See Optional Features Section for other available options.
Valve Parts in Contact with Fluids
Body Brass 304 Stainless Steel
Seals and Discs NBR and FKM
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel
Springs 302 Stainless Steel / 17-7 PH Stainless Steel
Shading Coil Copper
Sleeve PA
Seats Graphite-filled PTFE
Standard
Coil and
Class of
Insulation
Watt Rating and Power
Consumption Spare Coil Part Number
AC General Purpose Explosionproof
Watts
VA
Holding
VA
Inrush AC AC
F 16.1 35 115 272610 272614
F 20.1 45 140 272610 272614
Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz. 24, 110, 115, 220, 230 volts
AC, 50 Hz. Other voltages are available when required.
Note: No combination 120/60, 110/50 coil available.
Must order either 120/60 or 110/50, etc.