Product Overview

4
3/2
SERIES
8314
3-WAY
Features
No minimum operating pressure required
The original 3-way valve design
Simplest valve for basic 3-way piloting operation, only a
spring and two moving parts
Moderate flow pilots, smaller control valves and actuators
Can also be used for low-volume fluid diversion
• High speed general service
Direct Acting
General Service Solenoid Valves
Brass or Stainless Steel Bodies
1/8" and 1/4" NPT
2
3
1
NC
NO
U
Solenoid Enclosures
Nominal Ambient Temp. Ranges
The nominal limitation of 32˚F (0˚C) is advisable for
any valve that might contain moisture (water vapor).
AC: -13˚F to 131˚F (-25˚C to 55˚C)*
DC: -13˚F to 131˚F (-25˚C to 55˚C)
*Max. ambient for explosionproof (EF) is 125˚F (52˚C)
Optional: For AC, the max. ambient temperature is
140˚F (60˚C) with Class H coil (with or without prefix EF)
Refer to Engineering Section for details.
Approvals
CSA certified. UL listed General Purpose Valves.
Meets applicable CE directives.
SIL 3 capable per IEC 61508 on normally closed const.
Third party certification provided by EXIDA.
Refer to Engineering Section for details
.
Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X.
Optional: Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9.
(To order, add prefix “EF” to catalog number.)
See Optional Features Section for other available options.
Options
Mounting bracket (suffix MB)
Quarter-turn manual operator with screw slot (suffix MS)
Viton (suffix V)
Oxygen (suffix N)
Silicon Free (suffix SF)
45
% ^ )
Valve Parts in Contact with Fluids
Body Brass Cast 304 Stainless Steel
Seals and Discs NBR (Upper Disk - FKM)
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel
Core Springs 302 Stainless Steel
Shading Coil Copper Silver
Core Guide CA
Standard
Coil and
Class of
Insulation
Watt Rating and Power
Consumption Spare Coil Part Number
DC
Watts
AC General Purpose Explosionproof
Watts
VA
Holding
VA
Inrush AC DC AC DC
F 11.6 10.1 25 50 238610 238710 238614 238714
Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220, 440 volts AC, 50 Hz).
6, 12, 24, 120, 240 volts DC. Must be specified when ordering. Other voltages are
available when required.
Electrical
Construction