User`s guide
Setting Up the MultiVoice Gateway Hardware
Interpreting the MultiVoice Gateway LEDs
MultiVoice Gateway for the MAX— User’s Guide Preliminary November 23, 1998 3-9
Table 3-2 lists and describes each LED on the front panel of the Redundant MultiVoice
Gateway.
MAX 2000
The following figure shows the location of LEDs on the MAX 2000 front panel.
Figure 3-10. Location of the MAX 2000 LEDs
Refer to the following table to understand each LED.
Table 3-2. Redundant MultiVoice Gateway LEDs
LED Description
Power On when the Redundant MultiVoice Gateway power supply is on.
A Fail On only if there is a failure on power supply A. That is, if one or more of the
voltages on the A side (+5, +3.3, +12, -12, -5) has failed.
B Fail On only when there is a failure on power supply B, (if one or more of the
voltages on the B side (+5, +3.3, +12, -12, -5) has failed.
Fan On when the fans are functioning properly (if +12 VDC from either A or B is
good.) If this LED is off, then a fan is not working.
Table 3-3. MAX 2000 LEDs
LED Description
pwr This LED is on when the MAX power is on.
act This LED is ON if there is activity on the Ethernet interface.