User`s guide
MultiVoice Gateway Technical Specifications
Alarm relay operating specifications
MultiVoice Gateway for the MAX— User’s Guide Preliminary November 23, 1998 C-3
The base system of a redundant power MultiVoice Gateway or MultiVoice Gateway 6000
weighs 41 lbs (18.6 kg). A fully loaded system weighs 56 lbs (25.5 kg). The redundant power
MultiVoice Gateway has the dimensions 7.0" x 17.5" x 12" (17.8 cm x 44.5 cm x 30.5 cm).
Alarm relay operating specifications
On the back panel of the Ascend unit is a pair of alarm-relay terminal-block contacts that
remains open during normal operation. The contacts close during loss of power, hardware
failure, or reset.
The maximum rated load for the alarm relay is:
• 1 amp at 30 Vdc.
• 0.6 amp at 60 Vdc.
• 0.6 amp at 60 Vac.
!
Caution: To reduce the risk of electric shock, do not connect the alarm circuit to a device
with an output exceeding 30 Vrms, 42.4 Vpeak, or 60 Vdc.
Additional details on the technical specifications for the MAX 6000, MAX 4000 and MAX
2000 MultiVoice Gateways may be found in the Getting Started Guide for that particular