User`s guide
Configuring Frame Relay
Monitoring Frame Relay connections
MultiVoice Gateway for the MAX— User’s Guide Preliminary November 23, 1998 7-13
Displaying link management information
To display Link Management Information (LMI) for each link activated by a Frame Relay
profile, use the lmi option. For example:
ascend% show fr lmi
T1_617D LMI for fr1
Invalid Unnumbered info 0 Invalid Prot Disc 0
Invalid Dummy Call Ref 0 Invalid Msg Type 0
Invalid Status Message 0 Invalid Lock Shift 0
Invalid Information ID 0 Invalid Report Type 0
Num Status Enqs Sent 0 Num Status Msgs Rcvd 0
Num Update Status Rcvd 0 Num Status Timeouts 2779
LMI is not on for fr1-temp
LMI is not on for fr1-temp-9
ANSI T1.617 Annex D local in-channel signaling protocol is the basis for this information.
(For a full definition of each of the fields reported, see Annex D.)
Displaying DLCI status
To display the status of each DLCI, use the dlci option. For example:
ascend% show fr dlci
DLCIs for fr1
DLCIs for fr1-temp
eng-lab-236-Cir DLCI = 17 Status = ACTIVE
input pkts 0 output pkts 0
input octets 0 output octets 0
input FECN 0 input DE 0
input BECN 0
last time status changed: 03/05/1997 14:44:17
DLCIs for fr1-temp-9
eng-lab-236-Cir-9 DLCI = 16 Status = ACTIVE
input pkts 0 output pkts 0
input octets 0 output octets 0
input FECN 0 input DE 0
input BECN 0
last time status changed: 03/05/1997 14:45:07
DLCIs not assigned
The MultiVoice Gateway reports DLCI information using these fields:
Field Description
DLCI DLCI number.
Status ACTIVE if the connection is up or INACTIVE if not.
input pkts Number of frames the interface has received.
output pkts Number of frames the interface has transmitted.