User`s guide

7-10 Preliminary November 23, 1998 MultiVoice Gateway for the MAX— User’s Guide
Configuring Frame Relay
Configuring Connection profiles for Frame Relay
RADIUS user profiles). This example shows the Connection profile that assigns a DLCI and
passes the data stream out to a Frame Relay switch. Figure 7-9 shows the network.
Figure 7-9. Gateway connections
In this example, the MultiVoice Gateway communicates with a remote Frame Relay switch by
using ATT-NNI, a Frame Relay profile. To configure this link:
1 Open a Connection profile.
2 Specify the station name, activate the profile, and specify FR encapsulation:
Ethernet
Connections
Station=gateway-1
Active=Yes
Encaps=FR
3 Enable IP routing and specify the address of the remote IP router:
Route IP=Yes
Ip options...
LAN Adrs=10.2.3.4/24
4 Open the Encaps Options subprofile, specify the name of the Frame Relay profile with a
nailed connection to the Frame Relay switch, and specify the DLCI assigned by the Frame
Relay administrator:
Encaps options...
FR Prof=ATT-NNI
DLCI=55
Circuit=N/A
5 Close the Connection profile.
NO LINK