User`s guide
7-8 Preliminary November 23, 1998 MultiVoice Gateway for the MAX— User’s Guide
Configuring Frame Relay
Configuring Connection profiles for Frame Relay
To configure the Frame Relay profile for this UNI-DTE link:
1 Open a Frame Relay profile.
2 Assign the profile a name and activate it:
Ethernet
Frame Relay
Name=ATT-DTE
Active=Yes
3 Set the FR Type to DTE:
FR Type=DTE
4 Set up the nailed connection to the remote switch, and specify the data service for the link.
For example:
Call Type=Nailed
Nailed Grp=1
Data Svc=64k
5 Specify the link management protocol and its configuration parameters. For example:
Link Mgmt=Q.933A
N391=6
DTE N392=3
DTE N393=4
T391=10
6 Close the Frame Relay profile.
Configuring Connection profiles for Frame Relay
All connections that use Frame Relay must specify the name of a configured Frame Relay
profile as the data link between the MultiVoice Gateway and the Frame Relay network.
Forwarded or routed connections over the Frame Relay link use the parameters shown in the
following examples:
Ethernet
Answer
Encaps...
PPP=Yes
FR=Yes
PPP Options...
Route IP=Yes
For gateway connections:
Ethernet
Connections
Encaps=FR
Encaps options...
FR Prof=pacbell
DLCI=16
Circuit=N/A
Route IP=Yes
Ip options...
LAN Adrs=10.2.3.4/24