User`s guide

6-16 Preliminary November 23, 1998 MultiVoice Gateway for the MAX— User’s Guide
Configuring MultiVoice
MultiVoice configuration examples
3 Set the Precedence parameter by pressing Enter to toggle through the list of hexadecimal
values which set the bit0 through bit2 of the ToS byte. For Example:
Ethernet
Mod Config
Precedence=100
The default is 101. You may toggle through and select values (Hexadecimal) representing
these processing priorities, as defined by RFC791:
4 Set the TOS parameter by pressing Enter to toggle through a list of processing cost options
for bit3 through bit6 of the ToS byte. For Example:
Ethernet
Mod Config
TOS=Minimize Delay
This parameter defaults to Minimize Delay. You may toggle through and select from
the following values (assigning the associated bit values to the ToS byte) for this
parameter, as defined by RFC1349:
Configuring Gateway call volumes
To configure the call volume for a MultiVoice Gateway:
1 Open the Ethernet > Mod Config > VOIP Options menu.
2 Set the Max VOIP calls parameter by pressing Enter to open the edit field, and entering a
value between 1 and the built-in maximum call volume for the MultiVoice Gateway. For
Example:
Ethernet
Mod Config
Max VOIP Calls=64
Parameter value Processing priority
000 Routine
001 Priority
010 Immediate
011 Flash
100 Flash Override
101 CRITIC/ECP (default)
110 Internetwork Control
111 Network Control
Parameter value Bit values
Minimize Delay 1000
Maximize Throughput 0100
Maximize Reliability 0010
Minimize Cost 0001
Normal (network control) 0000