158 Asanté IntraCore 36000 Series
logging sendmail destination-email Email recipients of alert messages GC
logging sendmail Enables SMTP event handling GC
show logging sendmail Displays SMTP event handler settings NE, PE
15.3.8 Time Commands
The system clock can be dynamically set by polling a set of specified time servers (NTP or SNTP), or by
using information broadcast by local time servers.
Command Function Mode
sntp client Accepts time from specified time servers GC
sntp server Specifies one or more time servers GC
sntp poll Sets the interval at which the client polls for time GC
sntp broadcast client Accepts time from any time broadcast server GC
show sntp Shows current SNTP configuration settings NE, PE
clock timezone Sets the time zone for the switch’s internal clock GC
Calendar set Sets the system date and time PE
show calendar Displays the current date and time setting NE, PE
15.3 9 System Status Commands
The following table lists the system status commands.
Command Function Mode
show startup-config Displays the contents of the configuration file (stored in flash
memory) that is used to start up the system
PE
show running-config Displays the configuration data currently in use PE
show system Displays system information NE, PE
show users Shows all active console and Telnet sessions, including user name,
idle time, and IP address of Telnet clients
NE, PE
show version Displays version information for the system NE, PE
15.3.10 Frame Size Commands
The following table lists the frame size commands.
Command Function Mode