User`s manual
152 Asanté IntraCore 36000 Series
Chapter 15: Configuration Guide
This chapter provides information about each of the features and an overview of the CLI commands needed
to configure, manage and maintain the switch. For more complete information about the commands refer to
Chapter 16: Command Reference.
15.1 Line Commands
You can access the onboard configuration program by attaching a VT100 compatible device to the server’s
serial port. These commands are used to set communication parameters for the serial port or Telnet (For
example, a virtual terminal).
Command Function Mode
line Identifies a specific line for configuration and starts the line configuration
mode.
GC
login Enables password checking at login. LC
password Specifies a password on a line. LC
exec-timeout Sets the interval that the command interpreter waits until input is detected. LC
password-thresh Sets the password intrusion threshold, which limits the number of failed logon
attempts.
LC
silent-time Sets the amount of time the management console is inaccessible after the
number of unsuccessful logon attempts exceeds the threshold set by the
password-thresh command. This command only applies to the serial port.
LC
databits Sets the number of data bits per character that are interpreted and generated
by hardware. This command only applies to the serial port.
LC
parity Defines the generation of a parity bit. This command only applies to the serial
port.
LC
speed Sets the terminal baud rate. This command only applies to the serial port. LC
stopbits Sets the number of the stop bits transmitted per byte. This command only
applies to the serial port.
LC
disconnect Terminates a line connection. PE
show line Displays a terminal line's parameters. NE, PE
15.2 General Commands
The following table lists the general commands and describes the functions and command modes of each
command.
Command Function Mode
enable Activates privileged mode NE