Cabling and Voltage Requirements
Page 2-5
Figure 2-7 FriendlyNet FS4016E front panel
The back panel of the FS4016E contains a 100-240 VAC power connector.
There are no other controls or indicators. See Figure 2-8.
Figure 2-8 FriendlyNet FS4016E back panel
Note: The FS4016E does not have a power switch. The
FS4016E is automatically powered on as soon as the power
cord is connected between the FS4016E and a power outlet.
Cabling and Voltage Requirements
This section describes the cabling and voltage requirements of the Switches.
Cabling Requirements
100Base-TX requires the use of data-grade Category 5) UTP (unshielded
twisted-pair) cable. Category 3 wiring may be used for 10Base-T.
Important! Some installations have Category 5 cabling but
do not have wall outlets and/or wiring closet punch-down
blocks that meet Category 5 requirements.
100Base-TX requires that all wiring and accessories meet
EIA/TIA 568B specifications for proper operation. When
wiring a 100Base-TX network, make sure that the entire
cable plant meets specifications.