AsantéHub 2072RPU Chassis Installation Guide • Introducing the Asanté 2072RPU Chassis on page 3 • Installation on page 6 • Replacing a Power Supply on page 8 • Technical Specifications on page 9
AsantéHub 2072RPU Chassis Installation Guide Technical Support Asanté Technologies is committed to providing you with reliable products and excellent technical support. Please contact us with any questions, concerns, or suggestions.You can reach us by phone, letter, or electronic mail, from 6:00 AM to 6:00 PM, PST at: Technical Support Asanté Technologies, Inc. 821 Fox Lane San Jose, CA 95131 (800) 622-7464 AppleLink address: ASANTE.TECH Internet address: support@asante.
Introducing the Asanté 2072RPU Chassis Introducing the Asanté 2072RPU Chassis The AsantéHub 2072RPU (Redundant Power Supply) Chassis is a dual segment, departmental Ethernet concentrator configured with two load-sharing power supplies, either of which can assume the total power budget for the device should one fail. If a failure occurs in one power supply, the remaining power supply will automatically take up the additional load.
AsantéHub 2072RPU Chassis Installation Guide The Asanté 2072RPU chassis has the following features: ❏ Seven slots to accept a variety of multiport repeater modules, allowing you to add nodes when needed.
Installation Installation This section explains how to install the 2072RPU chassis into a rack or onto a desk.
AsantéHub 2072RPU Chassis Installation Guide Rack Mounting the Chassis To rack mount the chassis, do the following steps: Mark the desired location on the rack. 1 2 Fasten the brackets to the chassis, using the hardware provided. 3 Fasten the chassis to the rack, (get an assistant to hold it in place if necessary), using the screws provided.
Installation Powering Up the Hub This section explains how to power up the hub for functionality. If you are installing more than one hub, you may want to repeat this procedure for each hub before attaching any device or net work connections. 1 To power up the hub, do the following steps: Make sure the power toggle switch is in the off position on the back panel. ❖ Note: Never remove or insert the power cords with the power switch turned on.
AsantéHub 2072RPU Chassis Installation Guide Replacing a Power Supply The AsantéHub 2072RPU is powered by two identical power supplies. Replacing either one of the units can be done with power on the hub.There is no need to shut down the hub and remove it from network service.To replace a power supply, follow these simple instructions and refer to the accompanying illustration.
Technical Specifications Technical Specifications The technical specifications for the Asanté 2072RPU Chassis are as follows: Power Requirements: Input Voltage: 100-240VAC, 50-60Hz Single phase; continuous voltage input range Input Current: 3A @ 100 VAC (max.) 1.5A @ 220 V 5A/250V Fast Blow Fuse Electromagnetic Emissions: Meets FCC/VDE Class A requirement Safety: Designed in accordance with UL 1950, CSA 22.2 No. 220, IEC 950,TUV and VDE requirements.
AsantéHub 2072RPU Chassis Installation Guide Manual P/N 06-00118-00 Page 10