Installation guide

Appendix
B
Ethernet
Specifications
Parameter 10Base2 10Base5
10BaseT
Cable Thin Thick
UTP
Impedance
50 ohms 50 ohms
100 ohms
Connector
on
cable
BNC
DB-15
RJ-45
Data transfer rate 10 Mbps 10 Mbps 10 Mbps
Topology
Bus
Bus/Star Star
Segment
length
185 meters
500 meters 100 meters
(maximum)
Distance between nodes
0.5 meter
1 meter
nla
(minimum)
Nodes
per
segment
30 500
nla
(maximum)
A few tips
10BaseT
Ethernet
The
wiring
normally
called
for
in
lOBaseT is
26
to
22
AWG,
which
cor-
responds
to
the
wire
gauge
of
telephone
unshielded
twisted-pair
cables.
You
need
two
pairs
of
wiring
for
each
node.
When
wiring
10BaseT
connections,
take
precautions
against
splitting
pairs. Be
sure
you
maintain
the
same
color
mates
for
each
pair
used
within
the
cable.
If
you
don't
follow
a
com-
mon
color
pairing,
you
can
mix
up
the
wires
preventing
the
Ethernet
signal
from
being
transmitted.
Be
sure
to
check
any
cabling
you
plan
to
use.
Older
cabling
may
not
be
of
adequate
quality
to
support
100
meters
between
a
device
and
the
hub.
B-1