GENERATOR MONITORING PANEL
To properly monitor the generator performance and load demand during operation, the generator installation shall
be equipped with a full instrument monitor panel.
Generator frequency in hertz
Line 1 current in amperes
Line 2 current in amperes
Generator voltage in volts
The program shall support the accumulation of elapsed generator hours. Generator hours shall be displayed.
OUTLETS AND CIRCUITS
The generator and or shore power shall supply the 120/240 volt electrical equipment and outlets outlined below.
Proper circuit protection shall be installed as noted:
Two (2) 120 volt exterior outlets, one (1) each side rear of body.
The outlet receptacle(s) shall be 20 amp, twist-lock (NEMA L5-20R).