Technical information
Norman Wells Fire Department
SVI Emergency Vehicles
NORNWLR-0002 11/02/12
Page 32 of 63
STREETSIDE COMPARTMENT - REAR (S3)
The interior useable compartment width shall be approximately 35.0" wide x 23" deep.
The compartment door opening shall be approximately 28.0" wide.
This compartment shall have a ROM roll-up door.
• The roll-up door slats and the door trim components shall be painted to match the single tone exterior
color.
• The door shall be equipped with a CPI harsh environment mechanical type door ajar switch located inside
compartment interior lower door track.
• There shall be NO keyed lock on this roll-up compartment door.
A compartment threshold protection plate shall be installed on the bottom edge of the compartment door opening.
The threshold protection shall be fabricated from an aluminum extrusion with an anodized exterior finish.
COMPARTMENT LAYOUT
• There shall be vertically mounted aluminum shelf-trac for specified component installation.
• There shall be three (3) adjustable shelf/shelves approximately 22" deep. Each shelf shall be fabricated from
3/16" 3003 aluminum sheet with a 2" vertical flange along the front and rear edges
• There shall be one (1) 1,000 lbs. slide-out tray(s) with a SlideMaster painted structural steel base
approximately 20" deep and as wide as the compartment layout or door opening permits located below the
level of the chassis frame rails. Each slide base shall have a gravity latch which will lock the tray in the closed
and full extension positions. Each tray shall be fabricated from 3/16" 3003 aluminum sheet and shall have
welded corners to form a box type tray surface with an internal depth of approximately 3 ½”.
− 3M™ Diamond Grade™ Conspicuity striping shall be provided on the front and side faces of the tray. The
striping shall be 2" wide and red/white in color.
• The floor of the compartment above the frame rails shall cover the area directly above the frame rails ONLY
(non-extended floor).
• Two (2) OnScene 64" Access LED compartment lights, vertically mounted.
• There shall be one (1) 120 volt outlet(s) located in this compartment on the forward wall unless noted
otherwise.
• The outlet receptacle(s) shall be 20 amp, straight-blade (NEMA 5-20R).
There shall be one (1) 120 volt outlet strip(s) approximately 4' long with straight blade household type outlets
provided with this outlet. Exact mounting location shall be specified by the Norman Wells Fire Department at the
pre-construction meeting.
− Outlet(s) shall be powered through the on-board shore power system.
• One (1) OnScene 9" LED ground light shall be provided below the body.