Technical information
Norman Wells Fire Department
SVI Emergency Vehicles
NORNWLR-0002 11/02/12
Page 29 of 63
STREETSIDE COMPARTMENT - FRONT (S1)
The interior useable compartment width shall be approximately 56.0" wide.
The compartment door opening shall be approximately 49.0" wide.
This compartment shall have a ROM roll-up door.
• The roll-up door slats and the door trim components shall be painted to match the single tone exterior
color.
• The door shall be equipped with a CPI harsh environment mechanical type door ajar switch located inside
compartment interior lower door track.
• There shall be NO keyed lock on this roll-up compartment door.
A compartment threshold protection plate shall be installed on the bottom edge of the compartment door opening.
The threshold protection shall be fabricated from an aluminum extrusion with an anodized exterior finish.
COMPARTMENT LAYOUT
• There shall be vertically mounted aluminum shelf-trac for specified component installation.
• There shall be one (1) 1,000 lbs. slide-out tray(s) with a SlideMaster painted structural steel base
approximately 92" deep and as wide as the compartment layout or door opening permits, capable of
extending out either side of the body located above the level of the chassis frame rails. Each slide base shall
have a gravity latch which will lock the tray in the closed and full extension positions. Each tray shall be
fabricated from 3/16" 3003 aluminum sheet and shall have welded corners to form a box type tray surface
with an internal depth of approximately 3 ½”.
− There shall be one (1) vertical partition(s) installed on tray dividing the tray into left and right sides. Each
vertical partition shall be horizontally adjustable; mounted on aluminum shelf trac on tray floor.
− 3M™ Diamond Grade™ Conspicuity striping shall be provided on the front and side faces of the tray. The
striping shall be 2" wide and red/white in color.
• There shall be one (1) transverse module fabricated from 3/16” (.188) 3003H-14 aluminum alloy smooth
sheet. The module will be designed for the following long tools and equipment:
− One (1) Norman Wells Fire Department supplied stokes basket(s). Dimensions of the stokes basket are
85” x 24” x 9” high.
− One (1) Norman Wells Fire Department supplied backboard(s) shall be stored inside specified stoke
basket.
− There shall be one (1) OnScene Solutions cargo straps provided to secure the stored equipment.
• The apparatus shall be provided with two (2) 25,000 BTU hot water type heater(s). The heater(s) shall be
connected to the chassis engine cooling system with shut-off valves and shall have a two-speed, 12 volt
blower.
• The floor of the compartment above the frame rails shall be extended to the interior edge of the door. The
floor shall have a 2" vertical lip and a 1" return to increase strength.