Specifications
SVI Trucks
Freightliner 4-Door Demo
SVI #917 01/05/15
71
LOADCENTER
The loadcenter shall be a Cutler Hammer, BR Series, specifically designed for protection and distribution of
120/240 volt AC, such as lighting and small motor branch circuits. The loadcenter enclosure shall be made of 16
gauge galvanized sheet steel. The galvanized coating provides corrosion protection and as such does not require
paint. All trims used on the BR Loadcenter shall be chromate sealed and finished with electro disposition epoxy
paint (ASA61) which exceeds requirements for outdoor and indoor applications. A combination surface/flush
cover with integral door shall be supplied.
The loadcenter shall be UL/CSA listed, NO EXCEPTIONS will be allowed.
GENERATOR MONITORING PANEL
To properly monitor the generator performance and load demand during operation, the generator installation shall
be equipped with a full instrument monitor panel.
Generator frequency in hertz
Line 1 current in amperes
Line 2 current in amperes
Generator voltage in volts
The program shall support the accumulation of elapsed generator hours. Generator hours shall be displayed.
SHORE POWER INLET - BATTERY CHARGER
The above mentioned shore power inlet, and battery conditioner shall be specified in the 12 volt section.
OUTLETS AND CIRCUITS
The generator and or shore power shall supply the 120/240 volt electrical equipment and outlets outlined below.
Proper circuit protection shall be installed as noted:
Two (2) 120 volt exterior outlets, one (1) each side near rear wheel well area.
The outlet receptacle(s) shall be 20 amp, straight-blade (NEMA 5-20R).