Specifications
SVI Trucks
Freightliner 4-Door Demo
SVI #917 01/05/15
53
REAR COMPARTMENT - CENTER (RC1)
The rear center compartment shall be closed to both side rear compartments.
The rear center compartment shall begin just above the bumper height and be as high as the side compartments,
unless specified otherwise. The body sub-frame shall extend at least 20" into the compartment to allow for the
spring loaded body mounts. Compartment shall be as deep as possible below sub-frame to maximize storage.
The interior useable compartment width shall be approximately 45.0" wide.
The compartment door opening shall be approximately 38.0" wide.
This compartment shall have a ROM roll-up door.
The roll-up door shall have an unpainted satin aluminum finish on the door slats and the door trim
components.
The door shall be equipped with a CPI harsh environment mechanical type door ajar switch located inside
compartment interior lower door track.
A keyed cylinder lock shall be provided in the bottom portion of the roll-up door.
One (1) nylon strap shall be provided to assist in closing the door. The strap shall be fastened to the left side
of the lower inside door sill. The strap shall extend from the left side of the lower inside door sill to a footman
loop attached to the center of the left side of the door frame.
A compartment threshold protection plate shall be installed on the bottom edge of the compartment door
opening. The threshold protection shall be fabricated from an aluminum extrusion with an anodized exterior
finish.
COMPARTMENT LAYOUT
There shall be vertically mounted aluminum Shelf-Trac for specified component installation. Shelf-Trac
extrusion shall have side extruded channels for use in mounting or securing special ancillary items, without
need for drilling into body.
There shall be one (1) 400 lbs. slide-out tray(s) approximately 24" deep and as wide as the compartment
layout or door opening permits. The tray top shall be fabricated from 3/16" 3003 aluminum sheet with a 3"
vertical lip and welded corners to form a box type tray surface. The sliding tracks shall extend 100% of the
slide length. The tray assembly shall utilize a pneumatic cylinder mounted on underside to hold the tray in
both the extended and closed positions.
There shall be one (1) OnScene Solutions 81 series aluminum tray base with 100% extension, and rating of
1,000 lbs. Slide-out tray(s) base shall be approximately 46" deep and as wide as the compartment layout or
door opening permits located above the body subframe and shall be vertically adjustable in height. Each slide
shall have a cable operated, spring loaded latch complimented by a large hand opening and red pull handle
(Pull to Release) which will lock the tray in the closed and full extension positions. Each tray shall be
fabricated from 3/16" 3003 aluminum sheet and shall have welded corners to form a box type tray surface
with an internal depth of approximately 3 ½”.
Two (2) Fire Department supplied hydraulic hose reel(s) with electric rewind shall be installed. The rewind
button for each reel shall be located adjacent to the reel it controls.
The hydraulic reel shall be equipped with Fire Department supplied hydraulic hose. Contractor shall provide
plastic hose stop on hose end.