Specifications

SVI Trucks
Freightliner 4-Door Demo
SVI #917 01/05/15
31
CAB CRASH TEST CERTIFICATION
A cab crash test certification from the fire apparatus manufacturer shall be provided with the equipment. A copy of
this certification shall be included with the bid.
NOTE: There shall be no exception to any portion of the cab integrity certification requirements. Nonconformance
shall lead to immediate rejection of bid.
The certification shall state that the cab does meet or exceed the requirements below:
1) European Occupant Protection Standard ECE Regulation No. 29.
2) SAE J2422 Cab Roof Strength Evaluation - Quasi-Static Loading Heavy Trucks.
CAB MIRRORS, DRIVER ADJUSTABLE
Section 14.3.5 of the NFPA 1901 Standards, 2009 edition, requires all primary rear view mirrors used by the
driver to be adjustable from the driver's position.
CAB STEP COVER AND BATTERY COMPARTMENT
The stock chassis step and fuel tank brackets shall be overlaid with 3/16" aluminum tread plate covers. The
stepping surface of the covers will be a non-slip NFPA approved stepping surface.
The following options will be cut into the step cover:
BATTERY CHARGING RECEPTACLE LOCATION
The specified battery charging receptacle and/or display panel shall be located on front face of specified cab step
cover.
HUB AND NUT COVERS
Front and rear wheels shall be provided with stainless steel hub caps and wheel nut covers.
MUDFLAPS
There shall be 1/4" rubber mudflaps provided and installed behind each set of tires to prevent throwing road
debris and lower road spray.
AIR BRAKE SYSTEM QUICK BUILD-UP
The air brake quick build-up system shall be supplied from the specified automatic electric compressor in order to
maintain full operating air pressure while the vehicle is not running.
The quick buildup system shall provide sufficient air pressure so that the apparatus has no brake drag and is able
to stop under the intended operating conditions following the 60-second buildup time.
ROAD EMERGENCY SAFETY KIT
One (1) set of three (3) dual faced triangular warning flares with fold away base complete with storage case per
DOT requirements shall be provided with the completed apparatus.
One (1) 2.5 lb. ABC type vehicle fire extinguisher with bracket per DOT requirements shall be provided and
mounted inside cab area.