Specifications

ST. PETERSBURG FIRE & RESCUE
AIR / LIGHT APPARATUS
SVI #865 PRODUCTION SPECIFICATION
SVI #865 04/26/13
71
Light Tower Floodlights
The Command Light CL615-MH2 shall be equipped with the following bank of floodlights:
Floodlight manufacturer:
Command Light
Number of lamp heads:
Four (4) 1,500 watt Quartz Halogen
Two (2) 1,000 watt Metal Halide
Voltage:
120/240 volts
Total watts of light tower:
8,000 watts
Configuration: The light heads shall be mounted with three (3) on each side of
the light tower, giving two (2) vertical lines of three (3) when the
lights are in the upright position.
Light Tower Backlight Option
A backlight option shall be provided on the light tower. The lower pair of light heads shall be capable of being rotated
about a horizontal axis 180 degree, providing light down on the vehicle or to the opposite side of the vehicle while allowing
the fixed lights to remain pointed at the scene.
The hand-held remote control shall have an additional switch supplied for the backlight rotation option.
Light Tower Paint
The light tower shall be electrostatically powder coated with a hammer tone gray color.
Light Tower Controls
The light tower shall be operated with a hand-held 12-foot umbilical line remote control. The storage station for the
remote control unit shall be equipped with a button to activate the "Auto-Park" automatic nesting feature. The remote
control shall be located per the itemized compartment list and include;
Three (3) switches, one (1) for each light bank.
One (1) light bank rotation switch.
One (1) switch for elevating lower and upper stage.
One (1) indicator light to indicate when light bank is out of the roof nesting position.
One (1) indicator light to indicate when light bank is rotated to proper nesting position.
Light Tower Mounting
The specified light tower(s) shall be recessed into the roof of body to allow light tower(s) to be stowed below roof level.
The floor and side walls of recessed area shall be fabricated as a separate module from 3/16" aluminum treadplate with
an overlapping 3" flange around perimeter roof line. The recessed area shall be completely water tight. All electrical
connections made to light tower shall be located on sidewalls for a water tight connection.
The recessed area shall have two (2) water drain holes (in opposite corners) with flexible 1" diameter hose routed to the
area below the body.