Specifications
ST. PETERSBURG FIRE & RESCUE
AIR / LIGHT APPARATUS
SVI #865 PRODUCTION SPECIFICATION
SVI #865 04/26/13
46
CURBSIDE COMPARTMENT - REAR (C3)
The interior useable compartment width shall be approximately 49.0" wide.
The compartment door opening shall be approximately 42.0" wide.
This compartment shall have a ROM roll-up door.
• The roll-up door slats and the door trim components shall be painted to match the single tone exterior color.
• The door shall be equipped with a CPI harsh environment mechanical type door ajar switch located inside
compartment interior lower door track.
• The roll-up doors shall be equipped with an electric power lock system. All doors shall be locked or unlocked with
activation from a single switch located in the cab.
A compartment threshold protection plate shall be installed on the bottom edge of the compartment door opening. The
threshold protection shall be fabricated from an aluminum extrusion with an anodized exterior finish.
COMPARTMENT LAYOUT
• There shall be vertically mounted aluminum shelf-trac for specified component installation.
• There shall be two (2) OnScene Solutions 84 series aluminum tray base with 90% extension, and rating of 250 lbs.
Slide-out tray(s) base shall be approximately 24" deep and as wide as the compartment layout or door opening
permits. It shall be located above the level of the chassis frame rails and shall be vertically adjustable in height. Each
slide shall have a cable operated, spring loaded latch complimented by a large hand opening and red pull handle (Pull
to Release) which will hold the tray in the closed position. Each tray shall be fabricated from 3/16" 3003 aluminum
sheet and have welded corners to form a box type tray surface with an internal depth of approximately 3 ½”.
• The floor of the compartment above the frame rails shall cover the area directly above the frame rails ONLY (non-
extended floor).
• Two (2) OnScene 64" Access LED compartment lights, vertically mounted.
• One (1) 12 volt terminal block(s) installed to provide 12 VDC power for equipment supplied by the St. Petersburg Fire
and Rescue. Exact location shall be determined at the pre-construction meeting.
SHOP NOTES
Shall be located on the lower back wall at the forward side of the compartment, adjacent to the 120V Quad outlet.
• There shall be one (1) 120 volt quad outlet box located in this compartment on the lower back wall, adjacent to
specified 12 volt terminal block..
• The outlet receptacle(s) shall be 20 amp, straight-blade (NEMA 5-20R).
• Outlet(s) shall be powered by both the on-board generator and shore power system through a relay system.
• Two (2) 3-1/2" x 3-1/2" black plastic louvered vents shall be provided in the lower compartment.