Specifications

ST. PETERSBURG FIRE & RESCUE
AIR / LIGHT APPARATUS
SVI #865 PRODUCTION SPECIFICATION
SVI #865 04/26/13
39
The floor of the compartment above the frame rails shall cover the area directly above the frame rails ONLY (non-
extended floor).
Two (2) OnScene 64" Access LED compartment lights, vertically mounted.
The controls for the specified light tower(s).
There shall be one (1) 240 volt outlet(s) located in this compartment mounted on the forward wall unless noted
otherwise.
SHOP NOTES
This outlet shall be dedicated for the Sierra Booster and located accordingly.
The outlet receptacle(s) shall be 20 amp, twist-lock (NEMA L6-20R).
Outlet(s) shall be powered through the on-board generator system.
One (1) Bauer model CFSII-2S, two (2) position SCBA cylinder filling station with built-in 4-bank manual cascade
control panel shall be provided and installed with proper reinforcement for weight of fill station.
A Sierra 9000A-2, 5,000 PSI electrically driven air booster shall be provided with the air system.
An air storage refill port shall be provided on the fill station.
One (1) high pressure air hose reel gauge(s), adjustable regulator(s), and fill control(s) shall be provided on front
panel with outlet port located on the rear of the fill station.
The fill station fill whip(s) shall terminate in a high pressure 4,500 PSI, CGA-347 threaded SCBA connectors.
One (1) OnScene 9" LED ground light shall be provided below the body.