EXTERIOR COMPARTMENT DOORS
ROLL-UP DOOR CONSTRUCTION - ROBINSON (ROM)
The apparatus shall be equipped with Robinson ROM Series III roll-up exterior compartment doors. Robinson roll-up
doors shall be complete with the following features;
• Doors shall be front roll with drum positioned at upper front portion of compartment to afford maximum clearances and
head room for mounting equipment to ceiling of compartment
• There shall be a non-abrasive side brush seals
• Every slat must have interlocking end shoes to prevent slat from moving side-to-side and binding the door
• Between each slat must be a co-extruded PVC inner seal to prevent metal-to-metal contact and to repel moisture.
This inner seal is not visible to detract from appearance of door
• Slats are to have interlocking joints with a folding locking flange to provide security and prevent penetration by sharp
objects
• Slats to be double-wall extrusion 1.366" high by .315" thick. Exterior surface to be flat and interior surface to be
concave to prevent loose equipment from interfering with door operation
• Latch system to be a full width one piece lift bar operable by one (1) hand
• A 2" wide finger pull integrated into the bottom rail extrusion for easy one (1) hand opening and closing
• Clip system that connects the curtain slats to the operator drum which allows for easy tension adjustment without
tools
• Each roll-up door shall have a 4" diameter counterbalance operator drum to assist in lifting the door.
• Track shall be one-piece aluminum that has an attaching flange and finishing flange incorporated into its design
• Drip rail will have specially designed seal that prevents the seal from scratching the door
• Bottom rail extrusion must have smooth back to prevent loose equipment from jamming the door
• Bottom rail to have "V" shaped double seal to prevent water and debris from entering the compartment
• Standard replacement parts to be shipped from the United States and available in as little as 48 hours
• Will be free from manufacturing defects for a period of up to 7 years from date of purchase provided that the Product
is used under conditions of normal use, that regular periodic maintenance and service is performed and that the
product was installed in accordance with R•O•M’s instructions.
Each shutter door shall decrease the compartment door frame opening approximately 2.00" in width and approximately
4.50" in height for the bottom section of door assembly.
The specified retroreflective stripe material shall be applied on the roll-up compartment doors. The stripe shall be
precision machine cut for each door slat of the roll-up doors. Under no circumstance will the stripe material be cut on roll-
up door surface.