Specifications
ST. PETERSBURG FIRE & RESCUE
AIR / LIGHT APPARATUS
SVI #865 PRODUCTION SPECIFICATION
SVI #865 04/26/13
27
CAB STEP COVER AND BATTERY COMPARTMENT
The stock chassis step and fuel tank brackets shall be overlaid with 1/8" aluminum tread plate covers. The stepping
surface of the covers will be overlaid with a non-slip NFPA approved stepping surface. There will be a removable panel to
access and replace the chassis batteries and a hinged fuel fill access door.
The following options will be cut into the step cover:
BATTERY JUMPER STUDS
Two (2) battery jumper studs, one (1) positive with a red weather cover, and one (1) negative with a black weather cover
shall be provided in the lower front portion of the driver step area. Jumper studs shall be identified with color coded label.
These studs shall allow this vehicle to be jump started due to a battery failure, or to allow easy access to assist another
vehicle.
MUDFLAPS
There shall be rubber mudflaps furnished and installed behind each set of tires.
AIR BRAKE SYSTEM QUICK BUILD-UP
There shall be one (1) Milton male quick connector type air shoreline inlet to provide air to the chassis air tanks from an
external source compressed air shoreline hookup in order to maintain full operating air pressure while the vehicle is not
running. Air inlet shall be located near driver's door. The female end of the connector shall be supplied by the St.
Petersburg Fire and Rescue.
The quick buildup system shall provide sufficient air pressure so that the apparatus has no brake drag and is able to stop
under the intended operating conditions following the 60-second buildup time.
ROAD EMERGENCY SAFETY KIT
One (1) set of three (3) dual faced triangular warning flares with fold away base complete with storage case per DOT
requirements shall be provided with the completed apparatus.
One (1) 2.5 lb. ABC type vehicle fire extinguisher with bracket per DOT requirements shall be provided with the completed
apparatus.
INTERIOR OUTLET
There shall be one (1) 120 VAC, 20 amp, duplex straight-blade receptacle (NEMA 5-20R) outlet(s) provided on the
officers side of the cab center console.
• Outlet(s) shall be powered by both the on-board generator and shore power system through a relay system.