ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION Contents INTERNET IN-PROCESS SITE .............................................................................................................................................. 5 VEHICLE STABILITY SUPPLIED WITH CAB/CHASSIS ....................................................................................................... 5 ROADABILITY.......................................................................................
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION OCCUPANT RESTRAINT INDICATOR ................................................................................................................................ 26 STORAGE MODULE ............................................................................................................................................................ 26 IGNITION KEY ..............................................................................
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION COMPARTMENT LAYOUT ................................................................................................................................................... 38 STREETSIDE COMPARTMENT - ABOVE REAR WHEELS (S2) ....................................................................................... 40 COMPARTMENT LAYOUT ...................................................................................................
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION WARRANTY PERIOD ........................................................................................................................................................... 62 GENERATOR SPLASH GUARD .......................................................................................................................................... 62 GENERATOR MOUNTING ....................................................................
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION INTERNET IN-PROCESS SITE The Bidder shall post and maintain a website where the St. Petersburg Fire and Rescue will be able to view digital images of their apparatus as its being manufactured. The digital images shall be posted once a week starting when the body begins production or when the cab/chassis arrives and shall continue until the final completion of the apparatus.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION CONSTRUCTION DOCUMENTATION The contractor shall supply, at the time of delivery, at least one (1) copy of the following documents: The manufacturers record of apparatus construction details, including the following information: 1. Owner’s name and address 2. Apparatus manufacturer, model, and serial number 3. Chassis make, model, and serial number a. GAWR of front and rear axles and GVWR b.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION 27. If the apparatus has a line voltage power source, the certification of the test for the power source 28. If the apparatus is equipped with an air system, air tank certificates, the SCBA fill station certification, and the results of the testing of the air system installation 29. Any other required manufacturer test data or reports.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION NFPA REQUIRED DOCUMENTATION FORMAT - CD-ROM The vehicle construction details and the operations and service documentation as required per NFPA 1901 latest edition shall be provided on a CD-ROM. These manuals shall be divided into sections for ease of reference. There shall be two (2) copies of the CD-ROM provided with the completed vehicle.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION If the apparatus is equipped with an auxiliary braking system, the Body Manufacturer shall road test the system to confirm that the system is functioning as intended by the auxiliary braking system manufacturer. If the apparatus is equipped with an air brake system, the service brakes shall bring the apparatus, when loaded to its GVWR, to a complete stop from an initial speed of 20 mph (32.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION 3. LOW VOLTAGE ALARM TEST The following test shall be started with the engine off and the battery voltage at or above 12 V for a 12 V nominal system, 24 V for a 24 V nominal system or 36 V for a 42 V nominal system. With the engine shut off, the total continuous electrical load shall be activated and shall continue to be applied until the excessive battery discharge alarm activates.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION The following conditions shall be recorded at least every 1/2 hour during the test: 1. 2. 3. 4.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION DIELECTRIC VOLTAGE WITHSTAND TEST The line voltage wiring and permanently connected devices and equipment shall be subjected to a dielectric voltage withstand test of 900 volts for one (1) minute. The testing shall be performed after all body work has been completed. The test shall be conducted as follows: 1. 2. 3. 4. 5.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION STRUCTURAL WARRANTY - TEN (10) YEARS The body shall be free of structural or design failure or workmanship for a period of ten (10) years, or 100,000 miles (or 160,934 kilometers), whichever occurs first, starting thirty (30) days after the original invoice date.
ST.
ST.
ST.
ST.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION STANDARD AIR SYSTEM PRESSURE PROTECTION AND 85 PSI PRESSURE PROTECTION FOR AIR HORN(S) STD U.S. FRONT BRAKE VALVE RELAY VALVE WITH 5-8 PSI CRACK PRESSURE, NO REAR PROPORTIONING VALVE BW AD-9 BRAKE LINE AIR DRYER WITH HEATER AIR DRYER FRAME MOUNTED STEEL AIR BRAKE RESERVOIRS BW DV-2 AUTO DRAIN VALVE WITH HEATER WET TANK Wheelbase & Frame 5650MM (222 INCH) WHEELBASE 11/32X3-1/2X10-15/16 INCH STEEL FRAME (8.73MMX277.8MM/0.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION POLISHING OF FUEL/HYDRAULIC TANK(S) WITH PAINTED BANDS FUEL TANK(S) FORWARD PLAIN STEP FINISH FUEL TANK CAP(S) ALLIANCE FUEL FILTER/WATER SEPARATOR EQUIFLO INBOARD FUEL SYSTEM HIGH TEMPERATURE REINFORCED NYLON FUEL LINE Tires GOODYEAR G661 HSA 12R22.5 16 PLY RADIAL FRONT TIRES (MATCH MARKED) GOODYEAR G288 11R22.
ST.
ST.
ST.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION CHASSIS MODIFICATIONS LUBRICATION AND TIRE DATA PLATE A permanent label in the driving compartment shall specify the quantity and type of the following fluids used in the vehicle and tire information: • • • • • • • • • • • • • • • • • Engine oil Engine coolant Chassis transmission fluid Pump transmission lubrication fluid . . (if applicable) Pump priming system fluid, if applicable . .
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION OVERALL HEIGHT, LENGTH DATA PLATE (US) The fire apparatus manufacturer shall permanently affix a high-visibility label in a location visible to the driver while seated. The label shall show the height of the completed fire apparatus in feet and inches, the length of the completed fire apparatus in feet and inches, and the GVWR in pounds.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION EXHAUST The exhaust system shall be as provided by cab/chassis manufacturer. The tailpipe may require some modifications for proper ground clearances and fit with body. The exhaust piping and discharge outlet shall be located or shielded so as not to expose any portion of the vehicle or equipment to excessive heating. Exhaust pipe discharge shall be directed away from any operator’s position or entry doors on body.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION OCCUPANT RESTRAINT INDICATOR The occupant restraint indicator shall have the following features; • • • Supports commercial and custom cab seating layouts; up to 12 seats Built-in audible alarm Use in conjunction with Vehicle Data Recorder (VDR) STORAGE MODULE A storage module shall be provided in the cab. The module shall be as large as possible and fabricated of 1/8" smooth aluminum.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION CAB STEP COVER AND BATTERY COMPARTMENT The stock chassis step and fuel tank brackets shall be overlaid with 1/8" aluminum tread plate covers. The stepping surface of the covers will be overlaid with a non-slip NFPA approved stepping surface. There will be a removable panel to access and replace the chassis batteries and a hinged fuel fill access door.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION BODY DESIGN The importance of public safety associated with emergency vehicles requires that the construction of this vehicle meet the following specifications. These specifications are written to establish the minimum level of quality and design. All Bidders shall be required to meet these minimum requirements.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION Compartment floors shall have a "sweep-out" design with door opening threshold positioned lower than compartment floor, permitting easy cleaning of compartments. Angles, lips, or door moldings are not acceptable in the base of compartment door opening. One-way rubber drain valves shall be provided in compartment floors so that a water hose may be used to flush-out compartment area.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION BODY MOUNTING The body subframe shall be fastened to the chassis frame with a minimum of six (6) spring loaded body mounts. Each mount shall be configured using a two-piece encapsulated slide bracket. The two (2) brackets shall be fabricated of heavy duty 1/4" thick steel and shall have a powder coat finish to prevent any corrosion.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION BODY PAINT SPECIFICATIONS BODY PAINT PREPARATION After the body and components have been fabricated they shall be disassembled prior to painting so when the vehicle is complete there shall be finish paint beneath the removable components. The body shall be totally removed from chassis during the paint process to insure the entire unit is covered.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION PAINT - ENVIRONMENTAL IMPACT The contractor shall meet or exceed all current State (his) regulations concerning paint operations. Pollution control shall include measures to protect the atmosphere, water and soil. PPG Delfleet® Evolution paint shall be free of all heavy metal (lead & chromate) components. Paint emissions from sanding and painting shall be filtered and collected.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION REFLECTIVE STRIPE REQUIREMENTS Material All retroreflective materials shall conform to the requirements of ASTM D 4956, Standard Specification for Retroreflective Sheeting for Traffic Control, Section 6.1.1 for Type I Sheeting. All retroreflective materials used that are colors not listed in ASTM D 4956, Section 6.1.1, shall have a minimum coefficient of retroreflection of 10 with observation angle of 0.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION CHEVRON STRIPE - CAB BUMPER A reflective stripe shall be affixed to the front of cab. The stripe or combination of stripes shall be a minimum of 4 in. (100 mm) in total width.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION LETTERING GRAPHICS PROOF A color graphics proof of the lettering layout shall be provided for approval by St. Petersburg Fire and Rescue prior to installation. The graphics proof shall be submitted to St. Petersburg Fire and Rescue on 8.5" x 11" sheets with front, sides, rear and plan views, each on one (1) sheet. In addition if there is any special art work an additional sheet shall be provided showing all details.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION EXTERIOR COMPARTMENT DOORS ROLL-UP DOOR CONSTRUCTION - ROBINSON (ROM) The apparatus shall be equipped with Robinson ROM Series III roll-up exterior compartment doors.
ST.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION STREETSIDE COMPARTMENT - FRONT (S1) The interior useable compartment space shall be approximately 70.0" wide. The compartment door opening shall be approximately 63.0" wide. This compartment shall have a ROM roll-up door. • The roll-up door slats and the door trim components shall be painted to match the single tone exterior color.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION − The floor of the compartment above the frame rails shall cover the area directly above the frame rails ONLY (nonextended floor). • Two (2) OnScene 64" Access LED compartment lights, vertically mounted. • The controls for the specified light tower(s). • There shall be one (1) 240 volt outlet(s) located in this compartment mounted on the forward wall unless noted otherwise.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION STREETSIDE COMPARTMENT - ABOVE REAR WHEELS (S2) The interior useable compartment width shall be approximately 64.0" wide. The compartment door opening shall be approximately 57.0" wide. This compartment shall have a ROM roll-up door. • The roll-up door slats and the door trim components shall be painted to match the single tone exterior color.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION − The cable reel shall equipped with 150' of 10/3 SEOW black cable, a molded plastic ball clamp, and a single heavy duty L5-30 twist-lock female plug at the end. SHOP NOTES There shall be a label at each reel stating: "FAN MUST PLUG DIRECTLY IN TO CORD REEL" − One (1) Akron model EJB series, cast aluminum electrical power distribution box with yellow powder coat painted finish shall be provided.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION STREETSIDE COMPARTMENT - REAR (S3) The interior useable compartment width shall be approximately 49.0" wide. The compartment door opening shall be approximately 42.0" wide. This compartment shall have a ROM roll-up door. − The roll-up door slats and the door trim components shall be painted to match the single tone exterior color.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION CURBSIDE COMPARTMENT - FRONT (C1) The interior useable compartment space shall be approximately 70.0" wide. The compartment door opening shall be approximately 63.0" wide. This compartment shall have a ROM roll-up door. • The roll-up door slats and the door trim components shall be painted to match the single tone exterior color.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION CURBSIDE COMPARTMENT - ABOVE REAR WHEEL (C2) The interior useable compartment width shall be approximately 64.0" wide. The compartment door opening shall be approximately 57.0" wide. This compartment shall have a ROM roll-up door. • The roll-up door slats and the door trim components shall be painted to match the single tone exterior color.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION − The cable reel shall equipped with 150' of 10/3 SEOW black cable, a molded plastic ball clamp, and a single heavy duty L5-30 twist-lock female plug at the end. SHOP NOTES Cord to be a different color, other than black or yellow if possible.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION CURBSIDE COMPARTMENT - REAR (C3) The interior useable compartment width shall be approximately 49.0" wide. The compartment door opening shall be approximately 42.0" wide. This compartment shall have a ROM roll-up door. • The roll-up door slats and the door trim components shall be painted to match the single tone exterior color.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION REAR COMPARTMENT - CENTER (RC1) The rear center compartment shall be closed to both side rear compartments. The rear center compartment shall start at the bottom of the body and shall be as high as the body permits. The interior useable compartment width shall be approximately 45.0" wide. The compartment door opening shall be approximately 38.0" wide. This compartment shall have a ROM roll-up door.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION − One (1) Hannay ECR1616-17-18 electric cable reel(s) capable of storing 150' of 10/3 electric cable. Reel(s) shall be designed to hold 110% of the capacity of cord length, with fully enclosed 45 amp, three (3) conductor collector rings. Reel(s) shall be mounted to channel structure that allows for side-to-side adjustment of reel position.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION SIDE BODY PROTECTION - RUB RAIL OnScene Solutions rub rails shall be provided below the compartment door openings on both the streetside and curbside. The rub rail shall be fabricated from 6063 extruded aluminum, measuring approximately 2-3/4" high x 1-3/8" thick with tapered aluminum end caps.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION LOW VOLTAGE ELECTRICAL SYSTEM- 12 VDC General Any low voltage electrical systems or warning devices installed on the fire apparatus shall be appropriate for the mounting location and intended electrical load. Where wire passes through sheet metal, grommets shall be used to protect wire and wire looms. Electrical connections shall be with double crimp water-tight heat shrink connectors.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION Wiring shall be uniquely identified at least every 2 ft (0.6 m) by color coding or permanent marking with a circuit function code. The identification shall reference a wiring diagram. Circuits shall be provided with properly rated low voltage overcurrent protective devices.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION The charge status of the battery shall be determined either by direct measurement of the battery charge or indirectly by monitoring the electrical system voltage. If electrical system voltage is monitored, the alarm shall sound if the system voltage at the battery or at the master load disconnect switch drops below 11.8 V for 12 V nominal systems, 23.6 V for 24 V nominal systems, or 35.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION CAB CONSOLE A center cab console shall be provided between the Driver's and Officer's seats. Console shall be as large as possible and fabricated of 1/8" smooth aluminum. A textured powder coat paint finish shall be provided for durability and finished appearance. The rear portion of the console shall be provided with open top storage for notebooks or maps. Two (2) adjustable dividers shall be provided in the storage area.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION BATTERY SYSTEM The battery connectors shall be heavy duty type with cables terminating in heat shrink loom. Heavy duty battery cables shall provide maximum power to the electrical system. Where required, the cables shall be shielded from exhaust tubing and the muffler. Large rubber grommets shall be provided where cables enter the battery compartment. Batteries shall be of the high-cycle type.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION SHORE POWER INLET One (1) Kussmaul 120 VAC, 20 amp shore power inlet with weather resistant snap cover shall be provided. The protective ground from the shoreline inlet shall be bonded to the vehicle frame. • • The outlet cover shall be yellow. The shore power plug shall be located near the Driver door area.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION REAR VIEW CAMERA There shall be one (1) ASA Voyager rear observation camera system provided and installed on completed unit. The system shall include one (1) model VCC150 high resolution CCD color camera installed on the rear body. The camera image shall be displayed on a model AOM713, 7" color flat panel display (up to 3 camera inputs) located within the driver's range of view.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION LICENSE PLATE LIGHT One (1) Arrow #437 chrome plated LED license plate light shall be installed on the rear of the body. License plate light shall be wired to the headlight circuit of chassis. A fastener system shall be provided for license plate installation. ELECTRONIC SIREN One (1) Federal EQ2B 200 watt, electronic siren/amplifier with digital output control head shall be provided.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION WARNING LIGHT PACKAGE Each apparatus shall have a system of optical warning devices that meets or exceeds the requirements of this section. The optical warning system shall consist of an upper and a lower warning level. The requirements for each level shall be met by the warning devices in that particular level without consideration of the warning devices in the other level.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION UPPER LEVEL OPTICAL WARNING DEVICES The upper-level optical warning devices shall be mounted as high and as close to the corner points of the apparatus as is practical to define the clearance lines of the apparatus. The upper-level optical warning devices shall not be mounted above the maximum height, specified by the device manufacturer.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION ZONES B AND D - SIDE WARNING LIGHTS UPPER REAR CORNER WARNING LIGHTS There shall be two (2) Whelen 900 series (9" x 7") Red Linear Super-LED lights (90RR5FRR) provided, one (1) each side. Each light shall have a red lens and chrome flange. The lights shall be switched at the 12 volt control panel in the cab.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION ZONE A - FRONT WARNING LIGHTS There shall be two (2) Whelen 600 series (6" x 4") red Linear Super-LED lights (60R02FRR) provided, one (1) each side. Each light shall have a red lens and chrome flange. The lights shall be switched at the 12 volt control panel in the cab.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION LINE VOLTAGE ELECTRICAL SYSTEM ONAN PTO GENERATOR The vehicle shall be equipped with an Onan Protec PTO generator system with a capacity of 25,000 watts at 120/240 VAC, 208/104 amps, single phase. Current frequency shall be stable at 60 hertz.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION GENERATOR MOUNTING The generator shall be mounted between the chassis frame rails. The generator mounting brackets shall be fabricated using heavy duty steel tubing, or structural channel. The generator mounting shall be bolted and removable so that the generator can be lowered from under apparatus for service, if necessary. The generator case shall not extend below the bottom edge of the apparatus body.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION GENERATOR MONITORING PANEL To properly monitor the generator performance and load demand during operation, the generator installation shall be equipped with a full instrument monitor panel. • • • • Generator frequency in hertz Line 1 current in amperes Line 2 current in amperes Generator voltage in volts The program shall support the accumulation of elapsed generator hours. Generator hours shall be displayed.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION Grounding Grounding shall be in accordance with 250.34(A) and 250.34(B) of NFPA 70. Ungrounded systems shall not be used. Only stranded or braided copper conductors shall be used for grounding and bonding. The grounded current-carrying conductor (neutral) shall be insulated from the equipment-grounding conductors and from the equipment enclosures and other grounded parts.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION Access shall be provided to permit both routine maintenance and removal of the power source for major servicing. The power source shall be located such that neither it nor its mounting brackets interfere with the routine maintenance of the fire apparatus. Instrumentation If the power source is rated at less than 3 kW, a “Power On” indicator shall be provided.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION All power supply assembly conductors, including neutral and grounding conductors, shall have an equivalent amperage rating and shall be sized to carry not less than 115 percent of the amperage of the nameplate current rating of the power source.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION Where the power source is 120/240 V and 120 V loads are connected, the apparatus manufacturer or line voltage system installer shall consider load balancing to the extent that it is possible. Wiring Methods Fixed wiring systems shall be limited to the following: 1.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION Wiring System Components Only stranded copper conductors with an insulation rated for temperatures of at least 194°F (90°C) and wet locations shall be used. Conductors in flexible cord shall be sized in accordance with Table 400.5(A) of NFPA 70. Conductors used in conduit shall be sized in accordance with 310.15, “Ampacities for Conductors Rated 0–2000 Volts,” of NFPA 70.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION Receptacles used for DC voltages shall be rated for DC service. Wiring Schematics An "As-Built" Wiring diagrams for line voltage systems shall be provided to include the following information; 1. 2. 3. 4. 5. 6. 7.
ST.
ST. PETERSBURG FIRE & RESCUE AIR / LIGHT APPARATUS SVI #865 PRODUCTION SPECIFICATION EQUIPMENT PAYLOAD WEIGHT ALLOWANCE In compliance with NFPA 1901 standards, the special service vehicle shall be designed for an equipment loading allowance of 4,000 lbs. of St. Petersburg Fire and Rescue provided loose equipment based on a 30,001 - 40,000 pound gross vehicle weight rating.