Technical data
AlphaWave Users Manual 3/21/2005
Page B-9
B.11 E
VENT
The AW unit records the events in the event log, which is 100 events
deep. The events in the log are identified by a unique event code.
The EVENT command is intended to read the log of events from the
unit. The unit responses to the EVENT command by sending the
event codes consecutively in order of occurrence.
B.12 B
OOT
The BOOT command is intended to reboot the unit using the factory
and user selectable configurations for system initialization. A new
unit will have the default values for user selectable parameters that
should be loaded in production.
The BOOT command also selects the real-time software/ firmware
image. The software loader after reboot runs the image selected by
BOOT command. The factory firmware image will be used if the up-
dated firmware is not loaded or if it is corrupted or has any other
problem.
BOOT [Image] [/?]
The Image specifies a selected real-time software image:
∗ FACT – selects the real-time software/firmware image;
∗ UPDT – selects the user updated real-time software/firmware
image.
B.13 S
AVE
The SAVE command is intended to store the unit’s currently used
configuration into the User Configuration file. The configuration
stored in the User Configuration file will be activated by automati-
cally after unit’s reboot.
Appendix B