The Alarm LED must indicate the SYNC Loss and BER exceeding the
defined threshold.
B.7 S
LEEP
The SLEEP command determines the sleep mode parameters. The
sleeping AW can be activated by real-time CLK, DTR/RTS lines, and
command received through TTL inputs. The user can select one, two,
or all three conditions.
SLEEP [Parameter Name] [Parameters List] [/?]
B.8 C
ONNECT
To connect the radio unit (local or remote) through the local mainte-
nance serial port, the CONNECT command must be used.
CONNECT [Unit_Numb] [/?]
Where the Unit_Numb is an assigned decimal number for the unit to
Parameter
Name
Parameter List
TTL1
0 – TTL_OUT1 = logic “1”
1 – TTL_OUT1 = TTL_IN1 (received from remote unit)
2 – TTL_OUT1 = TTL_IN1 and TTL_IN2 (received from remote
unit)
3 – TTL_OUT1 = TTL_IN1 or TTL_IN2 (received from remote unit)
TTL2
0 – TTL_OUT2 = logic “1”
1 – TTL_OUT2 = TTL_IN2 (received from remote unit)
2 – TTL_OUT2 = SYNC Loss
3 – TTL_OUT2 = BER > BERTH or SYNC Loss
BERTH
1 – BER Threshold >10
–3
(default threshold level for BER)
2 – BER Threshold BER >10
–4
Parameter
Name
Parameters List
CLK
0 – Do not activate by internal real-time clock
(1 – 255) – Activate by internal real-time clock after 100 to 25500
msec of sleeping
HW
0 – Do not activate through DTR/RTS lines
1 – Activate through DTR/RTS lines
TTL
0 – Do not activate by external sense lines
1 – Activate by external sense lines
GTS
0 – Disable Sleep mode (default)
(1 – 255) – Go to sleep mode if there is no activity in 10 to 2550
msec