Technical data
AlphaWave Users Manual 3/21/2005
A-1 Alpha-Wave Environmental Specifications
Parameter Specification
Temperature
Operating –30
o
c to +60
o
c (ETSI 300-019-1-3 Class 3.1
(E))
Storage –40
o
c to +80
o
c
Solar radiation 1000 w/m2 at +40
o
c
Vibration without Transporta-
tion Case
10 to 500 Hz; ± 0.35 mm, 5 cycles, 1 octave/
min within operating temperature range
(ISO 9022-36-08)
Bump
25g, 6 ms, 4000 shocks in each direction and
axis within operating temperature range
ISO9022-31-06 @ operating temperature min./max.
Drop without Transportation
Case
1.5 m once to all surfaces on to hardwood (50
mm) over concrete floor within operating tem-
perature range
Water, Sand, and Dust
Meets or exceeds the stan-
dard outlined in IEC 529 I.P.
67
(water-tight and dust-tight).
Rain: MIL506.4-I
Submersion: MIL512.4-I
Dust: MIL510.4-I
Humidity
(MIL-STD-810F Method 507.4-1)
Min 5 cycles/1 cycle = 48h
Max 60
o
C, max. RH 95% operating
Max 65
o
C, RH 95%, 65h (none operating)
Altitude
-1,000m under sea level to 8,500 m above sea
level
Compliance to IEC61000-4:
Radiated, radio frequency,
electromagnetic field immu-
nity
IEC61000-4-3 Level 3
Immunity to the conducted
disturbances induced by RF
field
IEC61000-4-6 Level 3
Power frequency magnetic
field immunity
IEC61000-4-8 Level 4
Electrostatic discharge
(contact and air discharge)
IEC61000-4-2 Level 4
Electronic Compliance
ETSI ETSI 300-113
FCC FCC Part 15
Industry Canada RSS-210
UL UL 1419
UL Hazardous Location Class 1, Div 2; Groups A, B, C, and D; hazard-
ous locations
FM Approved
Page A-2
Appendix A