Technical data

Transmitted Frame Counter (TFC) – displays the number of
transmitted frames since the beginning of the calculation.
Unrecoverable Frame Counter (UFC) – displays the number
of received frames that have not been recovered by FEC decoder
since the beginning of the calculation.
Lost Frame Counter (LFC) – displays the number of lost
frames since the beginning of the calculation.
Received Frame (RFC) – displays the number of received
frames since the beginning of the calculation.
Frame Loss Rate (FLR) – shows the ratio of the lost frame
number to the total number of frames, which should be received
since the beginning of the calculation.
The tabs (OEC, UEC, RBC, TFC, UFC, LFC, RFC, and FLR) are the
graphical representation of the monitoring parameters presented in
time domain.
7.2.3 V
IEWING RSL STATISTICS
The Receive Signal Level (RSL) Statistics dialog shows the current
level of received signal in dBm. The statistical measurement graph
displays up to 96 data points along the horizontal axis. The vertical
axis shows the signal level in dBm. This tab contains a control to
specify the measurement interval in seconds (the minimum interval
equals to 5 seconds). During the measurement process AWare alters
the diagram whenever the received signal’s diapason changes.
Figure 7-4: RSL Statistics
Page 7-4
AlphaWave Users Manual 3/21/2005
Chapter 7