Technical data

Reset – Resets the statistic information;
Run – gets the statistic information;
Close - Close statistic window;
Help - Help options for statistic window.
7.2.2 V
IEWING RX/TX STATISTICS
The Rx/Tx Statistics dialog window provides the AlphaWave specific
statistic information not covered by G.821 standard. This dialog con-
tains nine tabs where the first tab exposes the numerical values for
the monitoring parameters:
Figure 7-3: RX/TX Statistics
Observed Error Counter (OEC) – shows the number of errone-
ous bits that have been detected by FEC decoder since the begin-
ning of the calculation.
Uncorrected Error Counter (UEC) – shows the number of er-
roneous bits that have not been corrected by FEC decoder since
the beginning of the calculation.
Received Bit Counter (RBC) indicates the actual number of
bits received since the beginning of the calculation.
Bit Error Rate (BER) – shows the ratio of the number of cor-
rected errors to the number of bits received since the beginning
of the calculation.
Page 7-3
AlphaWave Users Manual 3/21/2005
Chapter 7