Technical data

orders the AlphaWave unit to switch on the testing receive mode
(TSTRX ON command).
Figure 6-8: RSL Calibration Box
The measurement procedure shall be as follows:
1. Set unit’s receiver for 440.000 MHz central frequency
2. Set signal generator to generate 440.00 MHz frequency with -
120 dBm output power level
3. Set Receive Test mode using TSTRX ON command (see also IS-
00003-14)
4. Save the RSSI value in the RSL/RSSI table using “Apply” button
(the TSTRX command is used to read the RSSI value from the
unit)
5. Increase the input signal by 6 dBm (for output generator)
6. Repeat steps 4 to 5 for up to -60 dBm
Closing this dialog box stops the testing mode of unit. To load the
RSSI/RSL Table into the unit, the Download FCFG dialog box must
be used (see section 6.4.2).
Page 6-11
AlphaWave Users Manual 3/21/2005
Chapter 6