Technical data
2 Select the Tools > Factory Configuration > Calibration Kit >
TCXO of AWare main menu bar.
6.3.2 ALC C
ALIBRATION TOOL
This option allows operator/technician to build the ALC Table used by
unit’s Automatic Level Control (ALC) module to set the precise value
of required output power level. The ALC Table lists the measure-
ments provided by unit’s built-in Power Detector for the output
power levels from 13 dBm to 33 dBm. The ALC Table also contains
the DAC gain and attenuation level for each output power level in
the list.
Figure 6-7: ALC Calibration Box
By opening the ALC Calibration Tool dialog box the operator/
technician first orders the AlphaWave unit to generate 511-bit length
pseudo-random sequence.
The measurement procedure shall be as follows:
Page 6-9
AlphaWave Users Manual 3/21/2005
Chapter 6