Technical data
6.2.1 CONFIGURING CHANNEL MAPPING
Figure 6-5: Channel Map for Dealer Configuration
The Dealer uses Channel Map tab to program frequencies and map
them to corresponding channels. The maximum number of available
channel for all ArWest radios is 32. The Channels List field shows all
programmed frequencies in the current dealer configuration. The
central frequencies are in MHz format and they have to be divisible
to minimum channel spacing – 6.25 kHz. The dealer can add and
remove channels from dealer configuration, also he can change cen-
tral frequency and channel mapping.
6.3 FACTORY CONFIGURATION TOOLS
The Factory Configuration tools is a set of software utilities intended
to create, export/import to/from external storage, and download to
unit factory configuration parameters (including calibration parame-
ters). The calibration parameters include TCXO tuning value (from 1
to 32), and ALC and RSSI/RSL calibration tables.
Note: The Calibration option is available only in the “Workshop”
version of AWare.
Page 6-7
AlphaWave Users Manual 3/21/2005
Chapter 6