Technical data
RXS is the receiver sensitivity as a function of the selected
modulation type and channel spacing:
PWR is the transmitter’s output power level and RSL is the
measured receive signal strength.
To activate BERT Test dialog box:
1. Select a unit name (icon) from the Site View pane.
2. Select the Tools > Test Kit > BERT Test >Transmit or Re-
ceive option of AWare main menu bar.
CS Modulation
-113 dBm 25 kHz DBPSK
-116 dBm 12.5 kHz DBPSK
-119 dBm 6.25 kHz DBPSK
-110 dBm 25 kHz DQPSK
-113 dBm 12.5 kHz DQPSK
-116 dBm 6.25 kHz DQPSK
-97 dBm 25 kHz D8PSK
-110 dBm 12.5 kHz D8PSK
-113 dBm 6.25 kHz D8PSK
-94 dBm 25 kHz D16QAM
-97 dBm 12.5 kHz D16QAM
-110 dBm 6.25 kHz D16QAM
Note: The Transmit mode of BER test is not applicable for the
receive-only systems.
The BERT test cannot be run for Simplex Transmitter since
the remote Simplex Receiver operating in receive-only
mode does not provide information needed for link quality
estimation.
The BER does not include the bits in the lost frames.
Page 6-5
AlphaWave Users Manual 3/21/2005
Chapter 6