INSTRUCTIONS FOR THE INSTALLER
Important notice:
The operations indicated below must be followed by authorised personnel exclusively, in
conformity with the regulations in force.
The manufacturing firm refuses all responsibility for damages to people, animals or things,
resulting from the failure to comply with such provisions.
This appliance shall be installed only by authorised persons and in accordance with the
manufacturer’s installation instructions, local gas fitting regulations, municipal building codes,
electrical wiring regulations, and any other statutory regulations. For Australia and New Zealand
this appliance must be installed by an authorised person in compliance with AS/NZS 5601.1 Gas
installations part 1: general installations, and AS/NZS 5601.2 Gas installations part 2: LP GAS
installations in caravans and boats for nonpropulsive purposes. For outside of Australia/New
Zealand refer to the relevant installation code for gas appliances in your country.
INSTALLATION
The installation kit contains the following:
- 1 natural gas regulator
- 1 elbow
- 1 manifold
- 1 fibre sealing washers
- 4 brackets for assembly
- 4 bracket screws
- 1 pack of cooktop to benchtop seals
- 1 duplicate rating label
For conversion to ULPG
- 1 Universal LPG sticker
- 1 injectors
Additional accessory for cooking with vessels
diameter 120mm or below
- 1 mini trivet
- 1 wok trivet
Installing the top
The appliance is designed to be embedded into heat-
resistant benchtop capable of withstanding 95°C.
Adjacent walls, cupboards and protection for
combustible materials.
Ensure that the appliance is installed in
accordance with clauses 6.2.5 and 6.10.1.1 of AS/
NZS5601.1, or clauses 6.9.1 and 6.9.5 of
AS/NZS5601. 2 with regard to clea rances
to combustible surfaces and materials, and
clearances to rangehoods and exhaust fans.
Clearance of 200mm from the periphery of
burners to vertical combustible surfaces is
required. Clearances to combustible surfaces
may be reduced only if combustible surfaces are
protected in accordance with clause 6.10.1.2 of
AS/NZS5601.1, or clause 6.9.2 of AS/NZS5601.2.
The equipment must not be installed near
inflammable materials, such as curtains,
cloths,etc. Make a cut out in the benchtop, with
the dimensions indicated in fig.3, respecting a
minimum distance of at least 50 mm from the back
edge of the installed device and 100 mm of the
adjacent side walls.
Rangehoods and exhaust fans* shall be installed
in accordance with the manufacturer’s relevant
instructions. However, in no case shall the
clearance between the highest part of the hob
of the gas cooking appliance and a range hood
be less than 600mm or, for an overhead exhaust
fan, 750mm. (*An exhaust fan is defined as a
mechanical device other than a rangehood for
moving air from one interior space to another, or