User Manual
INSTALLATION
Adapting the cooker
another type of gas
This operation may only be carried out by
an appropriately authorised person.
To adapt the cooker to be
another type of gas, the burner nozzles
must be exchanged and the flame adjusted.
Caution!
When leaving the factory, burners are
adapted to use the gas specified on their
data plates and guarantee cards.
In order to adapt the cooker to burn a
different type of gas, you should:
● Exchange nozzles (see tables below),
● Adjust the flame intensity.
Injector Table
Total Gas Consumption
Burner turndown flame must also be adjusted to 25% of the
A correct flame has distinct internal cones of blue colour. A short, humming
flame or long, yellow and smoking one, without clearly outlined cones, shows improper
quality of gas in the household piping or a damaged or soiled burner. In order to cheak a
flame, heat a burner for around 10 minutes with a full flame, and next turn the valve knob
to the turndown flame position. The flame should not go out or jump onto the nozzles.
Hotplate burners do not require adjustment of primary air.
INSTALLATION
Replacement of a burner
injector: Unscrew the
injector with special socket
spanner NO 7 and replace
with a new one according
to a type of gas(see
tables), page 12
Caution!
● Adapting the appliance to a different
type of gas than that indicated by the
manufacturer of the cooker on the
data plate, or purchasing a cooker for
a different type of gas than supplied to
the house, is exclusively the
responsibility of the user and the fitter.
● After adjustment is completed, affix a
label to the cooker indicating the type
of gas to which the cooker is now adapted.
In cookers with a safety device, a knob
with a surface burner safety valve is used,
(Fig.B). Knobs should be adjusted with the
burner switched on and set to the
economical flame position, using an
adjustment screwdriver of the 2.5mm size.
Fig. B
A knob with a
surface burner
safety valve
12
13
Upright
Burner
Gas type
Injector
TPP
NGC
Size(mm)
(kPa)
(MJ/h)
Auxiliary
Semi-rapid
Rapid
Wok
Natural gas
Universal
LPG
Auxiliary
Semi-rapid
Rapid
Wok
1.45
0.87
1.13
1.65
1.0
3.6
10.8
6.3
12.6
0.51
0.67
0.87
0.95
2.75
3.3
6.2
10.8
12.6
600mm
Upright
540mm
Burner
Gas type
Injector
TPP
NGC
Size(mm)
(kPa)
(MJ/h)
Auxiliary
Semi-rapid
Wok
Auxiliary
Semi-rapid
Wok
Natural gas
Universal
0.95
0.87
1.13
1.65
1.0
0.67
LPG
0.51
2.75
3.6
6.3x2
12.6
3.3
6.2x2
12.6
600mm
Natural gas 33.3MJ/h - Universal LPG 32.9MJ/h
540mm 540mm
Natural gas 28.8MJ/h - Universal LPG 28.3MJ/h
high flame, refer to page 13 for adjustment screw location.
In order to perform the turndown adjustment, remove the gas burner control knobs.
When converting to a different gas type refer to page 10; gas connection.
Fig. B
Economical