User Manual
24
Rev.13052022
INSTALLATION INSTRUCTIONS AND WARNINGS (INDOOR USE ONLY)
AS/NZS 5601 clause 6.10.1.7
BARBECUES IN RESIDENTIAL PREMISES
Barbecues in residential premises shall be installed such that—
• (a) measured horizontally, a vertical combustible surface less than 200 mm from the cooking surface area is protected in
accordance with Clause 6.10.1.2 for a height of 150 mm; and
• (b) the clearances shown in Table 6.8 are observed.
NOTES:
• 1. This Clause (6.10.1.7) applies to gas appliances designed for use without a cooking vessel where cooking fats can fall
on to and are up from a heated perforated plate, volcanic rock or similar refractory material.
• 2. Any combustible surfaces less than 1200 mm but not less than 600 mm from the cooking surface may be protected in
accordance with Clause 6.10.1.2. The ‘cooking surface area’ is dened as that part of the gas appliance where cooking
normally takes place and does not include those parts of the gas appliance containing control knobs.
This appliance must be installed by an authorised person in accordance with this instruction manual, AS/NZS 5601 – Gas
installations (installation and pipe sizing), local gas tting regulations, local electrical regulations, local water regulations, local
health regulations, Building Code of Australia and any other government authority.
This appliance is suitable for connection with rigid pipe or exible hose. The isolating manual shut-off valve connection point
must be accessible when the appliance is installed. Flexible hose assembly must be certied to AS/NZS 1869 class B or D, be
of appropriate internal diameter for the total gas consumption, be kept as short as possible (not exceeding 1200mm), must not
be in contact with the oor or any hot or sharp surfaces. The hose assembly must not be subject to strain, abrasion, kinking or
deformation.
Natural Gas: the supplied regulator must be tted to the appliance inlet connection. Gas pressure must be adjusted to 1.0 kPa
when approximately 50% of the burners are on high ame, the appliance test point is located on the regulator.
ULPG: the supplied test point adaptor must be tted to the appliance inlet connection. Gas pressure must be adjusted to 2.75
kPa, the appliance test point is located on the test point adaptor.
Gas leakage and operation of the appliance must be tested by the installer before leaving. Check burner ames are blue in
colour, stable and completely ignite at both high and low ame settings with no appreciable yellow tipping, carbon deposition,
lifting, oating, lighting back or objectionable odour. Test burners individually and in combination, When satised with the
operation of the cooker, please instruct the user on the correct method of operation.
Overhead clearances—(Measurement A) Range hoods and exhaust fans shall be installed in accordance with the manufacturer’s
relevant instructions. However, in no case shall the clearance between the highest part of the barbecue and a range hood be
less than 1200 mm, for an overhead exhaust fan, 1200mm.
Side clearances—(Measurements B, & C) Where B, measured from the edge of appliance to any vertical
combustible surface, or vertical combustible surface covered with toughened glass or sheet metal, is less than 200 mm, the
surface shall be protected to a height C of not less than 150 mm above the hob for the full dimension (width or depth) of the
cooking surface area.
NB: Use of engineered stone (e.g. Cesar stone) as a bench top is permitted providing temperatures upto 120°C are tolerated