User Manual
20
Rev.13052022
CONVERSION TO ANOTHER GAS TYPE MUST BE CARRIED OUT BY AN AUTHORISED SERVICE TECHNICIAN
CONVERSION PROCEDURE
NORMAL LPG TO NG
Regulator - ensure
arrow is pointing
the correct direction
Hose with tapered
thread - thread tape
required
• Disconnect and disassembled/remove plates, burners etc.
• Remove injectors and replace with correct sizes for each burner.
• Adjust aeration (X) per every burner
• Re-assemble burners.
• Turn gas on and test for leaks, repair if necessary.
• Light the burners and set the pressure to 1,00kPa.
• Turn burner “Low” setting and adjust setting accordingly.
• Check operation of ignition etc.
• Ensure data plate is changed with the new data plates supplied in the product.
For Natural Gas connection a bayonet connection point should be installed by a licensed gas tter prior to installing
the barbecue unit.