GAS TYPE (Applies to all models) NATURAL GAS UNIVERSAL LPG
Nominal heat input (MJ/h) / Per Burner 13 13
Injector diameter (1/100mm) 170 100
Number of injectors 1 1
Pressure (kPa 1 2,75
Primary air regulation (mm) 20mm 20mm
Adapting to different types of gas. Conversion to another gas type must be carried out by a authorised by a person.
If the appliance is congured for a different type of gas than that available, you have to replace the injectors with ones
corresponding to the type of gas to be used (see table above). The replacement will be made using an adequate 7 mm spanner
after having lowered the burners as in the following images. After replacing the injector, regulate the air to 20mm for natural gas
and to 20mm for LPG.
To adjust the minimum, after lighting the burner, remove the knob and the gasket below and rotate the screw of the tap (B - see
page 21), which should be totally closed for LPG and opened about 3/4 turn for natural gas, keeping in mind that a ame lower
than 3 mm may not even be “perceived” by the thermocouple of the tap. After regulating the minimums, replace the gaskets
and knobs.
1 - Unscrew the xing screws of the burner.