User Manual
Arturia Microbrute User’s Manual   39 
Wave Select 
The  LFO  offers  several  modulation  waveforms  that  can  be  selected  using 
the switch. The options are; square, sawtooth, and triangle waves. 
Amount 
The Amount knob regulates how wide the modulation coming from the LFO is. It 
allows you to attenuate the level of the signal to get more subtle effects. 
Rate 
The rate knob allows you to set the speed of the LFO. It allows for a range of .1Hz – 
200Hz. When the LFO is sync’d to MIDI Clock (via the settings accessed in the 
MicroBrute editor software) or the Sequencer, the rate control will change between 
fixed time divisions of the incoming or Seq clock. 
These sync’d rates are: 
4 measures, 2 measures, 1 measure, ½ note, ¼ note, 
 The Rate and the LFO sync can be set within the MicroBrute Editor. In the editor, you 
can set whether the LFO is Free-running or Reset on each note. 
  Free-running – a free running LFO will have a set rate that does not change. 
Reset – the LFO can reset to a default start point on each Note/Sequencer 
Gate. This allows you to have the LFO start at the same point on each note on 
message. 
Sync 
This will allow the LFO to run on it’s own clock (or external MIDI clock source) in the 
FREE setting or have it tied to the timing of the Sequencer with the SEQ setting. 
LFO Settings via the MicroBrute Editor 
There are a number of settings for the LFO that determine how it operates. These 
settings can be accessed via the MicroBrute Editor Software. 