System information

Artistic Licence Engineering Ltd. Micro-Scope 3a Manual
36 / 78
SNAPSHOT
DMX TO
MEMORY
The SNAPSHOT menu allows
any one of the twelve
memories to be filled with
data captured from the
DMX512 input. The Memory to be used is selected by the UP and
DOWN keys when the menu display is active. Press the MENU key
to take the snapshot. The process requires eight consecutive
frames of DMX512 to capture the data. The snapshot can be
aborted (for example if the DMX512 input fails) by pressing the
TOGGLE button.
When the data has been
successfully captured, the
display shows:
FILL
MEMORY
WITH
PATTERN
The FILL menu allows any
one of the twelve Memories
to be filled with a
symmetrical pattern of
channel levels.
The following keys are active:
LEFT Select one of the pre-defined patterns
RIGHT Select one of the pre-defined patterns
UP Increment the Preset number
DOWN Decrement the Preset number
TOGGLE Execute the Fill
Fill patterns are selected from the following list:
Name
Function
ALL CHAN OFF
Clear the Preset
ALL CHAN HALF
Set all channels to 50%
ALL CHAN ON
Set all channels to 100%
ODD CHAN ON
Set all odd channels (1,3,5..511) to 100%
EVEN CHAN ON
Set all even channels (2,4,6..512) to 100%
RAMP UP
Set incrementing ramp from channel 1 to 256
and 257 to 512
RAMP DOWN
RAMP DOWN Set decrementing ramp from
channel 1 to 256 and 257 to 512