System information
Artistic Licence Engineering Ltd. Micro-Scope 3a Manual
13 / 78
OVERVIEW
Micro-Scope is operated by the six front panel buttons. The buttons
function as follows:
MENU
The MENU key is used to select the operating mode of Micro-Scope.
Pressing MENU once will display the currently selected mode. The
LEFT and RIGHT cursor keys are then used to select a new operating
mode. The process is completed by pressing MENU a second time.
The MENU Key is held down whilst power is switched on to access
the Setup Menu.
TOGGLE!
When Micro-Scope is in DISPLAY RECEIVED DMX512, the TOGGLE
key is used to step through the different display formats (bar graph,
percent, decimal etc.).
In TRANSMIT mode, the TOGGLE key is used to invert the level of
the selected channel.
In TRANSMIT LAMP mode, the TOGGLE key selects each of the
automated tests in sequence.
LEFT RIGHT
When Micro-Scope is in DISPLAY RECEIVED DMX512, the LEFT and
RIGHT cursor keys are used to select a new base address.
In TRANSMIT DMX512 modes, the LEFT and RIGHT cursor keys
are used to select a new transmit channel.
If Micro-Scope is displaying the menu, the LEFT and RIGHT cursor
keys are used to select the next operating mode.
UP DOWN
The UP and DOWN cursor keys are used to increment or decrement
the level of the displayed data.
T H E C O N T R O L
S U R F A C E