Instruction manual

Artistic Licence
21
Down-Lynx UK
Features
DMX routing by Ethernet
Art-Net 3 and sACN compatible
Two DMX512 outputs
10BaseT Ethernet Port
DHCP supported
Power indicator
Data activity indicators
Compatible with DMX512-A
RDM V1.0 (E1.20 - 2006 ESTA
Standard)
Back Box supplied
Specification
Listing: CE FCC
IP Rating: Indoor use
Power: 2W
Input Voltage: 9-48VDC
Height: 85mm
Width: 146mm
Depth: 39mm
DMX Output Connections: XLR5
Network Connections: RJ45
Power Connection: RJ45 or IDC
Isolation Ethernet port: Isolated
Isolation Power input: Isolated
Isolation DMX A/B: Ground
Referenced
Down-Lynx converts Ethernet data into two universes of DMX512.
Down-Lynx is housed in a standard 'Two-Gang' panel that is compatible with
all standard UK conduit and surface mount boxes; back box supplied.
The Ethernet connection is made to the rear of the panel via an RJ45
connector. Power can be connected by a separate cable, or via the Ethernet
cable using the IEEE 802.3 standard.
The front panel provides two DMX512-A outlets which support RDM.
Configuration is simplicity itself. The three rotary dials are used to select the
required DMX512 universe.
Down-Lynx can be software upgraded via the network connection.
Up-Lynx UK
Features
DMX routing by Ethernet
Connect up to 256 DMX Universes
to one network
Two DMX512 inputs
10BaseT Ethernet Port
Compatible with DMX512-A
Power indicator
Data activity indicators
Art-Net Compatible
Back Box supplied
Specification
Listing: CE FCC
IP Rating: Indoor use
Power: 2W
Input Voltage: 9-48VDC
Height: 85mm
Width: 146mm
Depth: 39mm
DMX Input Connections: XLR5
Network Connections: RJ45
Power Connection: RJ45 or IDC
Isolation Ethernet port: Isolated
Isolation Power input: Isolated
Isolation DMX A/B: Non-Isolated
Up-Lynx is part of the growing range of Art-Net compliant Ethernet products.
Up-Lynx converts two universes of DMX512 into Art-Net Ethernet data.
Up-Lynx is housed in a standard 'Two-Gang' panel that is compatible with all
standard UK conduit and surface mount boxes, back box supplied.
The Ethernet connection is made to the rear of the panel via an RJ45
connector. Power can be connected by a separate cable, or via the Ethernet
cable using the IEEE 802.3 standard. A screw terminal connection for both
power and data is available to special order.
The front panel provides two DMX512-A inputs. Configuration is simplicity
itself. The three rotary dials are used to select the required DMX512 universe.
Up-Lynx can be software upgraded via the network connection.