Specifications

12
Code Function Setting Range Initial Setting
Intelligent
Output
Terminal
Setting
Function
Relation
with
Output
Terminal
Others
Output terminal active state
NO: Normally open
NC: Normally closed
Output terminal active state
NO: Normally open
NC: Normally closed
NO: AL0-AL2 is closed at alarm NC: AL0-AL2 opens at alarm
Intelligent
Output
Terminal
Active
State
- -
Function Setting Range
H01
H02
H202
H03
H203
H04
H204
H05
H205
H06
H206
H20
H220
H21
H221
H22
H222
H23
H223
H24
H224
H30
H230
H31
H231
H32
H232
H33
H233
H34
H234
00~02(code)
Hitachi standard/auto
Hitachi standard/auto
0.1~7.5
0.1~7.5
2 / 4 / 6 / 8
2 / 4 / 6 / 8
0~99
0~99
0~255
0~255
0~65.53
0~65.53
0~65.53
0~65.53
0~655.35
0~655.35
0~655.35
0~655.35
0~655.35
0~655.35
0~65.53
0~65.53
0~65.53
0~65.53
0~655.35
0~655.35
0~655.35
0~655.35
0~655.35
0~655.35
00
Hitachi standard
Hitachi standard
Factoty set
4
4
20
20
100
100
Factoty set
Auto-tuning setting
Motor data
Motor data, 2nd motor
Motor capacity
Motor capacity, 2nd motor
Motor poles setting
Motor polesetting, 2nd motor
Speed control response constant (Kp)
Speed control response constant (Kp), 2nd motor
Moter stabilization constant
Motor stabilization coustant, 2nd motor
Motor constant R1
Motor constant R1, 2nd motor
Motor constant R2
Motor constant R2, 2nd motor
Motor constant L
Motor constant L, 2nd motor
Motor constant Io
Motor constant Io, 2nd motor
Inertia (J)
Inertia (J), 2nd motor
Motor constant R1
Motor constant R1, 2nd motor
Motor constant R2
Motor constant R2, 2nd motor
Motor constant L
Motor constant L, 2nd motor
Motor constant Io
Motor constant Io, 2nd motor
Inertia (J)
Inertia (J), 2nd motor
H Group: Sensorless Vector Functions
Sensorless
Vectol
Contorol
Motor
Constant
Initial SettingCode
Auto
Tuning
Motor
Constant
0~200% of the inverter rated current
0.0 ~ 360.0 Hz
0.0 ~ 360.0 Hz
0.0 ~100.0%
0.0 ~255
0.0 ~255
(Reserved) Do not edit.
Differs depending on models
Inverter rated current
NC
NO
NO
0 Hz
0 Hz
3.0%
Code Function
00 RUN (Running signal)
01 FA1 (Frequency arrival signal:command arrival)
02 FA2 (Frequency arrival signal:setting or more)
03 OL (Overload advance notice signal)
04 OD (Output deviation for PID control)
05 AL (Alarm signal)
Code Function
00 RUN (Running signal)
01 FA1 (Frequency arrival signal:command arrival)
02 FA2 (Frequency arrival signal:setting or more)
03 OL (Overload advance notice signal)
04 OD (Output deviation for PID control)
05 AL (Alarm signal)
C21
Output terminal 1 setting
Output terminal 11 active state
Output terminal 12 active state
Alarm relay active state
Overload advance notice signal
Acceleration arrival signal frequency setting
Deceleration arrival signal frequency setting
PID deviation limit signal level setting
Frequency command adjust.(0-L terminal)
Frequency command adjust.(OI-L terminal)
C22
C23
FM terminal setting
A-F (Analog output frequency monitor)
A (Analog output current monitor)
D-F (Digital output frequency monitor)
Output terminal 2 setting
C24
C31
C32
C33
C41
C42
C43
C44
C81
C82
C91~C95
Alarm relay output terminal setting
Factoty set
Factoty set
AL
A-F
RUN
FA1