Specifications

MDR User Guide 101
Signal Termination
Signal DPIO-FI DPIO-FO DPIO-EI DPIO-EO DPIO-DI/LI DPIO-DO/LO
SUSPEND*
330Ω pull down
220Ω pull up
330Ω pull down
220Ω pull up
390Ω to GND on
both + and - wires
110Ω across
+ and – wires
110Ω across
+ and – wires
DIR*
330Ω pull down
220Ω pull up
330Ω pull down
220Ω pull up
NA NA NA
NRDY*
330Ω pull down
220Ω pull up
330Ω pull down
220Ω pull up
NA NA
110Ω across
+ and – wires
STROB
330Ω pull down
220Ω pull up
330Ω pull down
220Ω pull up
110Ω across
+ and – wires
390Ω to GND on
both + and - wires
110Ω across
+ and – wires
PSTROB
PSTROB*
110Ω across
+ and – wires
390Ω to GND on
both + and - wires
NA NA NA
DATA
27Ω series 110Ω across
+ and – wires
390Ω to GND on
both + and - wires
110Ω across
+ and – wires
DVALID
27Ω series 110Ω across
+ and – wires
390Ω to GND on
both + and - wires
110Ω across
+ and – wires
SYNC
27Ω series 110Ω across
+ and – wires
390Ω to GND on
both + and - wires
110Ω across
+ and – wires
PIO2:1
27Ω series¤ 27Ω series 110Ω across
+ and – wires
390Ω to GND on
both + and - wires
110Ω across
+ and – wires
110Ω across
+ and – wires
RES3
27Ω series¤ 27Ω series
NA NA
110Ω across
+ and – wires
RES2:1
27Ω series¤ 27Ω series
NA NA NA NA
¤ when connected
FPDP Options
The FPDP standard defines a number of signals, which may be used differently in
different modes of operation. This section describes their usage in the MDR.
Clocking
Input module (DPIO-FI)
Two separate clocks are provided on the FPDP. STROB is a single-ended clock
conforming to TTL levels, while PSTROB and /PSTROB is a differential Positive
Emitter-Coupled Logic version of the same clock. Either of these signals may be used on
a FPDP input module. However, the PSTROB, /PSTROB signal pair is preferable,
especially at higher clocking frequencies and when driving longer lines, since the noise
margin is improved over the TTL clock. A control register bit on the DPIO selects
between the two clocks. This choice between these two sorts of signals will be available
from the version 1.2 of the MDR.
Output module (DPIO-FO)
A replaceable oscillator is used to generate clocks when operating as data source. The
oscillator frequency can be used directly or be divided by 2, 4, or 8 by means of control
register bits. This can be setup with the item called
OutputFreqDivisor in the
DpioInfo section of the mdr.ini file.