Specifications

24 Chapter2
Verifying Performance
RF Port Selection Verification (Agilent 83220A only)
18.On the Agilent 83220A, using a short cable (<30cm - Part No. 10502A or similar) and 2
BNC to N-type adapters (Part No. 1250-0780 or similar), link the AUX RF IN to the RF
IN/OUT port.
19.From the To Screen field, select the SPECTRUM ANALYZER screen (select More then
SPEC ANL).
20.Verify the presence of an 1806 MHz signal, at a level of
20 dBm (+3 dB, 4 dB).
21.From the To Screen field, select the CW MEAS/AF ANALYZER screen (select More then
CW AF ANL).
22.Verify that the CW frequency is 1806 MHz
±32 Hz.
Heading Field Setting
RF Gen RF Output Amplitude RF IN/OUT
20.0 dBm
RF Analyzer Amplitude 20.0 dBm
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com