Technical data

Hardware Preparation and Installation
MVME2502 Installation and Use (6806800R96B)
29
2.3.1 Environmental Requirements
Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.
Table 2-1 Environmental Requirements
Characteristics Commercial Versions Extended Temperature Versions
Applicable Variants MVME2502-02120201E/S
MVME2502-02120202E/S
MVME2502-02100202E
MVME2502-02100202S
Cooling Method Forced Air Forced Air
Operating
Temperature
0°C to +55°C -40°C to +71°C
Storage -40°C to +85°C -50°C to +100°C
Vibration Sine
(10min/axis)
2 G, 5 to 500 Hz 5 G, 15 to 2000 Hz
Vibration Random
(1hr/axis)
0.002g2/Hz, 15 to 2000 Hz 0.04g2/Hz, 15 to 2000 Hz (8
GRMS)
2
Shock 20g/11 mS 30g/11 mS
Humidity to 95% RH (non-condensing) to 100% RH (non-condensing)
1. ft3/min
2. Flat 15-1000Hz, -6db/octave 1000Hz - 2000Hz [MIL-STD 810F Figure 514.5C-17]