Owner`s manual

8
Electrical Requirements and Installation
The following information is provided for hooking up electrical supply to
your new spa. A qualified, licensed, electrician must perform this work.
Failure to follow these instructions will terminate all warranty coverage
and can cause serious injury or death.
Codes and Compliance
Your export 50 Hz Artesian spa is preset out of factory to run 230V 3wires
30 amp max input. This product must always be connected to residual cur-
rent device (RCD) having a trip current of not more than 30mA.
Electrical Wiring
WARNING: Your spa must be wired by a certified electrician and
according to these instructions. Failure to do so will terminate all
warranties and all listings from the independent listing facility.
1) The Island Class Spa requires a 240 VAC dedicated system. The spa
must be hard wired to the power supply, with no plug-in connections,
extension cords, or sharing of service.
2) The spa requires that you run 6 (10 mm²) or 8 (8.4 mm²) AWG copper
wire, depending on the GFCI size. Do Not Use Aluminum Wire.
3) The power supply must have a suitable Ground Fault Circuit Inter-
rupter (GFCI), according to Section 422-20 of the National Electrical
Code, ANSI/NFPA 70-7987 or other national installation requirement
with a residual current device (RCD) having a trip current of not more
than 30 mA. This could be used as the shut-off switch, which must be
installed in plain view of the spa. This electrical service must be readily
accessible to the spa occupants, but must not be within 5 feet of the
spa.
4) Use only non-metallic conduit and fittings when installing power to
the spa.
5) After your spa has been positioned, route lines through the knockout
on the left or right front corner of the spa.
9
Picture of System Box Terminal
Connection for 60Hz
6) Connect the power to the spa
Connect each color to its respective terminal block location. The Ground
(green) wire must be connected to the grounding terminal which is outside
of the System box. The Grounding wire must first enter the system box
and then access the grounding terminal via a hole on the side of the box
adjacent to the grounding terminal as shown in the picture above.
C
WHT AC
T
J
1
J
J
J
J
3
J
4
HTR
HTR1
T
1
US
C
SS
US
A
F5
F4
B
a
boa
G
FO
:
S.
HO
B
C
NEUTRAL
W
HO
D
G
C
C
WHT AC
T
J
2
J
1
J
5
J
5
J
J
J
J
5
HTR
HTR1
T
1
US
V
C
SS
US
A
F5
F4
6
J
3
K4
2
3
B
a
boa
G
O
:
S.
HO
B
C
NEUTRAL
WHITE
HO
RED
240VAC SERVICE
240/120 VAC SERVICE
North American 60 Hz 3X JETS, 2 PUMP 4X/5X/6X JETS 2/3 PUMPS
Voltage 240VAC 240VAC
Max Current Draw 37A 48A
Number of Wires 4 4
GFCI 50A 60A