Owner`s manual

24
Temp/Set (80°F - 104°F / 26°C - 40°C)/ Freeze
Protection
Temp/Set (80°F - 104°F / 26°C - 40°C)
The start-up temperature is set to 100°F/37°C. The Last measured
temperature is constantly displayed on the LCD.
NOTE: The last measured spa temperature displayed is current
only when the pump has been running for at least 1 minute.
To display the set temperature, press the “Cool” or
“Warm” pad once.
To change the set temperature, press the pad a second time before
the LCD stops flashing.
Each press of the “Cool” or “Warm” pad will
continue to either lower of raise the set temperature respectively.
After three seconds, the LCD will stop flashing and display the
current spa temperature.
25
ML700 Quick Reference Guide*
Initial Start Up
When your spa is first acutated it will go into priming mode ( af-
ter displaying some configuration information). Please see the M-7
Installation instruction manual for complete instructions Power up
and pump priming.
The Priming mode will last for up to 4 minutes and then the spa will
begin to heat and maintain the water temperature in the Standard
mode. You can exit Priming mode early by pressing
“Warm” or “Cool”.
Time
When time hasn’t been programmed, the “Time”
icon flashes. (time settings on EL1000 and some EL 2000 systems
are not preserved in the event of power loss, time will have to be
reprogrammed upon each power up.)
Optional Filter Cycles (Summer Mode) cont...
Press “Mode” to see “SET STOP FILTER 1” and adjust the
time with “Warm” or “Cool” as done above.
Press “Mode”................to see “SET START FILTER 2” (PM cycle)
and proceed as above.
Pressing “Mode” will enter the new filter cycle times into
the system and display the current water temperature.
Freeze Protection
If the temperature sensors detect a drop to below 44°F/6.7°C within
the heater, the pump will automatically activate to provide freeze
protection. The equipment stays on until 4 minutes after the sen-
sors detect that the spa temperature has risen to 45°F/7.2°C or
higher. In cold climates, an additional freeze sensor may be added
to protect against freeze conditions that may not be sensed by the
standard sensors. Aux freeze sensor protection acts similarly ex-
cept with the temperature thresholds determined by the switch and
without a 4-minute delay in turnoff. See your dealer for details.